Laserfiche WebLink
COLORADO - CDPS W ET TEST REPORT FORM -ACUTE <br />PERNIITTEE Seneca Coal Company <br />'TYPE TEST: <br />"TEST RESULTS: <br />ROUTINE: XX <br />LC;,,' > 100°io <br />CDPS NO.: CO-0000221 OL'TF:1LL: O12 <br />ACCELERATED: TEST SPECIES: <br />STATISTICAL N~THOD: Binomial <br />TEST TIME & DATE: BEGIN 1315 PM 10/12/01 END 1320 PM 10/16/01 <br />D[L.UTIONS (°io EFFLUENT) <br />MEASUREMENTS 0% l2 G°/u ?5% 50°/u 75% l00% <br /># c, START OF TEST: 40 40 40 40 40 40 <br /># AL[VE AF"iER 24 HRS: 40 40 40 40 40 39 <br /># ALIVE AFTER 48 HRS: 40 40 40 40 40 39 <br /># ALIVE AFTER 72 HRS: 40 40 40 40 40 38 <br /># AL[VE AFTER 96 HRS: 40 40 40 40 40 38 <br />RECEIVING WATER USED FOR D[LUT[ON? NO TOTAL RESID. Cl - (mg/I): <O.l <br />fIARDNESS (mg/I): RECEIVQVG WATER: EFFLUENT: 840 RECON WATER: 100 <br />ALKALINITY (mg/I):RECEIVINGWRTER: EFFLUENT: 220 RECON W ATER: 80 <br />pH: <br />TOTAL AMMONIA AS N (mg/1): <br />WERE ALL TEST CONDITIONS IN CONFORMANCE WITH DIVISION GUIDELINES? YES <br />[F NO, LIST DEVIATIONS FROM TEST SPECIFICATIONS: <br />_~-- <br />LABORATORY: COMMERCIAL TESTING & ENGINEERING ANALYST: CG~,..,..~-` <br />COMMENTS. <br />4/14/99 <br />COMMEq CIAL TESTING & ENGINEERING CO. <br />Ongmal Copy Warermarxea ~~~ <br />For Vour Prorerroon <br />F-0fifi ..~.r .~ <br />CONTROL 8.3 100% EFFLUENT 8.4 <br />CONTROL 7.5 100% EFFLUENT 7.8 <br />[NITIAL l00%: <l.0 F1NAL l00%: <1.0 <br />INITIAL: <br />FINAL: <br />