My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
HYDRO21737
DRMS
>
Back File Migration
>
Hydrology
>
HYDRO21737
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 8:43:02 PM
Creation date
11/20/2007 2:29:58 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1977306
IBM Index Class Name
Hydrology
Doc Date
6/23/2005
Doc Name
water sampling reports
From
cotter
To
dmg
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
90
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PARTI <br />Page No. 5 <br />PermitNo.: CO-0036251 <br />.. MONITORING REQUIREMENTS <br />1. Frequency and Sample Type (Continued) <br />Where, based on a minimum of 5 samples, the permittee demonstrates to the satisfaction of the Division that the level of total <br />dissolved solids (TDS) in the effluent can be calculated based upon the level of electrical conductivity, the pemuttee may <br />measure and report TDS in terms of electrical conductivity. <br />C. DEFINITIONS OF TERMS <br />1. "Acute Toxicity" means there shall be no acute toxicity in the effluent from this discharge point. The acute toxicity limitation <br />is exceeded if 1) a statistically significant difference in mortality (at the 95% confidence level) is observed for either species <br />between the control and any dilution less that or equal to the identified IWC or 2) a species mortality in any dilution of <br />effluent (including 100% effluent) exceeds 50%. <br />2. "Composite" sample is a minimum of four (4) grab samples collected at equally spaced two (2) hour intervals and <br />proportioned according to flow. <br />3. "Continuous" measurement, is a measurement obtained from an automatic recording device which continually measures <br />provides measurements. <br />4. "Daily Maximum limitation" means the limitation for this parameter shall be applied as an instantaneous maximum (or, for <br />pH or DO, instantaneous minimum) value. The instantaneous value is defined as the analytical result of any individual <br />sample. DMRs shall include the maximum (and/or minimum) of all instantaneous values within the calendar month. Any <br />instantaneous value beyond the noted daily maximum limitation for the indicated parameter shall be considered a violation of <br />this permit. <br />5. "Dissolved (D) metals fraction" is defined in the Basic Standards and Methodoloeies for Surface Water 1002-31, as that <br />portion of a water and suspended sediment sample which passed through a 0.40 or 0.45 iINI (micron) membrane filter. <br />Determinations of "dissolved" constituents are made using the frltrate. This may include some very small (colloidal) <br />suspended pat[icies which passed through the membrane filter as well as the amount of substance present in true chemical <br />solution. <br />6. "Grab" sample, is a single "dip and take" sample so as to be representative of the parameter being monitored. <br />7. "In-situ" measurement is defined as a single reading, observation or measuuement taken in the field at the point of discharge. <br />8. "Instantaneous" measurement is a single reading, observation, or measurement performed on site using existing monitoring <br />facilities. <br />4. "Potentially dissolved (PD) metals fraction" is defined in the Basic Standards and Methodoloeies for Surface Water 1002-31, <br />as that portion of a constituent measured from the filtrate of a water and suspended sediment sample that was first treated with <br />nitric acid to a pH of 2 or less and let stand for 8 to 96 hours prior to sample filtration using a 0.40 or 0.45-uM {micron) <br />membrane filter. Note the "potentially dissolved" method cannot be used where nitric acid will interfere with the analytical <br />procedure used for the constituent measured. <br />10. "Quarterly measurement frequency" means samples maybe collected at any time during the calendar quarter if a continual <br />discharge occurs. If the discharge is intermittent, then samples shall be collected durir~n, the period that discharge occurs. <br />11. "Recorder" requires the continuous operation of a chart and/or totalizer (or drinking water rotor meters or pump hour meters <br />where previously approved.) <br />
The URL can be used to link to this page
Your browser does not support the video tag.