My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
HYDRO21632
DRMS
>
Back File Migration
>
Hydrology
>
HYDRO21632
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 8:42:59 PM
Creation date
11/20/2007 2:25:17 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1993030
IBM Index Class Name
Hydrology
Doc Date
5/10/1993
Doc Name
FINAL PERMIT COLO DISCHARGE PERMIT SYSTEM STORM WATER CERTIFICATION COG-500808 CRYSTALJACK TELLER CO
From
JOHN O BUCKNER
To
CDOH
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PART I <br />Page 7 <br />Permit No. COG-500000 <br />B. EFFLUENT LIMITATIONS AND CONDITIONS -PROCESS WATER DISCHARGE <br />Effluent Parameter Measurement Frequwcv d/ g/ Sample Tvce h/ <br />Flow, MGD Weekly Instantaneous <br />Oil and Crease, mg/l i/ Weekly Visual <br />pH, s.u. Monthly Greb <br />Total Suspended Solids, mg/1 Monthly Gtab <br />Total Dissolved Solids, mg/1 efj/ Quarterly Grab <br />Total Phosphorus (as P) mg/I f/ Quarterly Grab <br />Self-monitoring samples taken in compliance with the monitoring requirements specified above shall be taken <br />a[ the point of discharge prior to entering waters of the State. <br />b. Mineral mining and processing point source category - 40 !'FR 436 - subparts E (gypsum), F (asphaltic <br />mineral), G (asbestos and woflastonite), J (barite), K (fluorspar), L (salines from brine lakes), M (borax), N <br />{potash), O (sodium sulfate), V (bentonite), W (magrtesite), X (diatomite), Y (jade), Z (novaculite), AF <br />(tripoli), and asphalt batch plants located at any facility otherwise covered by this general permit: <br />No monitoring is required (unless specified by the Division). An annual report to the Division on whether or <br />not a discharge of process water has taken place at the facility is required (see Part I.D.3.b of the permit). <br />4. Flow Measurirra Device <br />If not already a part of the permitted facility, within ninety (90) days after Ne effective date of the certification, a <br />flow measuring device shall be installed to give representative values of effluent quantities at the respective discharge <br />point. A flow maec~~ring device will be applicable at all desigmted discharge points of process water. The flow <br />may also be determined by using the pump capacity multiplied by the length of time the pump is operated, provided <br />that the accuracy requirement (sx below) is met. <br />When the facility is not opereting, and no discharge is occurring (e.g., if it is shut down for the winter), a Flow <br />measuring device is not required to be on site. <br />At Ute request of the Water Quality Control Division, or the Environmental Protection Agency, the permittee shall <br />show proof of the accuracy of any flow-measuring device used in obtaining data submitted in the monitoring report. <br />The flow-measuring device must indicate values within ten (10) percent of the actual flow being discharged. <br />C. EFFLUEN'T' LIMITATIONS AND COND111ONS - STORMWATER DISCHARGE <br />(This section (I.C) applies to all facilities with a discharge of stormwater.) <br />Genera] Limitations <br />a. Stormwater discharges from the industrial activity shell not cause or threaten to cause pollution, contamination <br />or degradation of any State waters. <br />b. There shall be no discharge of sanitary waste waters firm toilets or related facilities. <br />c. No chemicals ate to be added to the discharge unless permission for the use of a spxific chemical is granted <br />by the permit issuing authority. In granting the use of such chemicals, additional limitations and monitoring <br />requirements may be imposed. <br />d. Bulk storage stntctures for petroleum products and other chemicals shall have adequate protxtion so as to <br />prevent any reasonable loss of the material from entering discharged waters or waters of the State. <br />
The URL can be used to link to this page
Your browser does not support the video tag.