Laserfiche WebLink
' . <br />~~~ I~~I~~~~~ I <br />PERIODIC INSPECTION FORM <br />- -~=YATER, SEDIMENT, DR SLURRY IMPOUNDMENTS <br />Inspectors Name: ~p5.'S ~..~~_- <br />NPDES ID. No.: CO-0000213 001 <br />Facility.Configuratign: Crass Valley Pond <br />Site Name: Impoundment ~ 001 <br />-Mine Name: New Horizon Mine Western Fuels-Co <br />Mine ID No.:CMLRD Permit M0008-81 -- <br />Owners Rep,: R. L:-Wade, Mine Manager <br />.- _. <br />Date: / ~J- `~~ ' <br />Date Last Inspected: 57-~7,.~3 <br />Location: 47N16W36BC <br />Location:2 mi: NW mf Nucla, Co. <br />CIRCLE OR NRITE IN APPROPRIATE RESPONSE <br />1. Foundation Preparation (removal of vegetation, stumps, topsoil) Ye No N/A <br />2. Lift thickness (inches): /2 iNc~~, Yee No N/A <br />3. Compaction according to approved plan: ~ No N/A <br />4. Burning (specify extent and location): Yes No, N/A <br />5. Angle of slope: 3:1 upstream, 3:1 downstream, Total = 6:1 <br />6. Seepage (specify location, color, and approx. volume) <br /> Frmm underdrain pipes: Yes No <br /> At isolated points on embankment slopes: Yes ~ N%A <br /> At natural hillside: Yes F~(~ N/A <br /> Over widespread areas: Yes ~ N/A <br /> From downstream foundation area: Yes m N/A <br /> "Bails" beneath stream or ponded water: Yes o N/A <br />7~ Cracks mr scarps on crest: Yes o N/A <br />8. Cracks or scarps mn slope: Yes o N/A <br />9. Sloughing or bulging mn slope: Yes ~g N/A <br />10. +Major ermsign problems: Yes ~IP~ N/A <br />11. Surface movements in valley bottom or on hillside: Yes ~g N/A <br />12. +Erosion of toe: Yes A~ N/A <br />13. +Water impounded against tae: Yes ~ N/R <br />14. Existing embankment freeboard (feet): ` ~ Feet, of <br />15. increase qr decrease in water level (feet): Feeta,,,,.~;~,~, <br />16. Cracks, bulging, or erosion on upstream face: Yes m N/A <br />17. Visible sumps or sinkholes in slurry surface: Yes N/A <br />18. +Clpgging <br /> Spillway channels and pipes: Yes ~o N/A <br /> Decant system: Yes (N~ N/A <br /> Diversion ditches: Yes N N/A <br />19. +Cracking or crushing of pipes <br /> Spillway pipes: Yes ~ N/A <br /> Decant system: Yes No N%A <br />2B. Trash racks clear and in place: Yes No N/A <br />+Majo r adverse changes to these items could cause inst nd should 6 e reported <br />tm th e Chief Engineer and Mine Manager for further ~~EeLST d verse conditi ons <br />noted in these items should normally be describe ~>~KpW}$~~6~ 'on, vol ume, etc.) <br />on pa ge two of this inspection form, p~;(„5 B;o ,, n <br />