My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
HYDRO20165
DRMS
>
Back File Migration
>
Hydrology
>
HYDRO20165
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 8:41:32 PM
Creation date
11/20/2007 1:23:39 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1977208
IBM Index Class Name
Hydrology
Doc Date
8/2/2004
Doc Name
Water Samples of 07/02/04
From
Paragon Analytics
To
CEMEX Inc.
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
53
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
fluoride batch. There were not more than 20 samples in each preparation <br />batch. <br />^ The method blank associated with each applicable batch was below the <br />reporting limit for the requested analytes. This indicates that no contaminants <br />were introduced to the samples during prepazation and analysis. <br />^ The LCS and LCSD were within the acceptance limits for all applicable <br />analyses. <br />^ All initial and continuing calibration blanks (ICB/CCB) associated with each <br />applicable analytical batch were below the reporting limit for the requested <br />analytes. <br />^ All initial and continuing calibration verifications (ICV/CCV) associated with <br />each applicable analytical batch were within the acceptance criteria for the <br />requested analytes. This indicates a valid calibration and stable instrument <br />conditions. <br />9. Matrix specific quality control procedures. <br />Sample 0407037-1 was designated as the quality control sample for the pH and <br />TDS analyses. Since a sample from this order number was not selected as a <br />quality control (QC) sample for alkalinity, fluoride and ion chromatography (IC), <br />matrix specific QC results are not included in this report. <br />^ A sample duplicate was prepazed and analyzed with the pH and TDS batches. <br />All guidance criteria for precision were met. <br />10. It was necessary to dilute the samples in order to bring the chloride and sulfate <br />concentrations into the analytical range of the ion chromatograph (IC). <br />Reduced aliquots were taken of the sample for the alkalinity and TDS analyses. <br />Reporting limits were elevated accordingly. <br />11. Manual integrations aze performed when needed to provide consistent and <br />defensible data following the guidelines in Paragon Analytics Standard Operating <br />Procedure 939 Revision 1. <br />000 U2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.