My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
PERMFILE44640
DRMS
>
Back File Migration
>
Permit File
>
500000
>
PERMFILE44640
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 10:47:06 PM
Creation date
11/20/2007 12:00:20 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
C1996083
IBM Index Class Name
Permit File
Doc Date
5/12/2003
Doc Name
Section 9 & Section 10 (report April 7, 2003)
Section_Exhibit Name
Volume VII Geotechnical Studies
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
66
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
M99238GE <br />• trench backfill may 'need to be tested abort every 100 linear feet <br />cf lift of backfili. <br />6.0 LIMITATIONS <br />It is the owner's and the owner's representatives' responsibility <br />to read this report and become familiar with the recommendations <br />and suggestions presented. We should be contacted if ar_y questions <br />arise concerning the geotechnical engineering aspects of this <br />project as a result of the information presented in this report. <br />The recommendations outlined above are based on our understanding <br />of the currently proposed construction. We are available to <br />discuss the details of our recommendations with you and revise them <br />where necessary. This geotechnical engineering report is based on <br />the proposed site development and scope of services as provided to <br />us by Mr. Jim Stove, J.E. Stover and Associates, on the type of <br />construction planned, existing site conditions at the time of the <br />field study, and on our findings. Should the planned, proposed use <br />of the site be altered, Lambert and Associates must be contacted, <br />since any such changes may make our suggestions and recommendations <br />inappropriate. This report should be used ONLY for the planned <br />• development for which this report was tailored and prepared, and <br />ONLY to meet information needs of the owner and the owner's repre- <br />sentatives. In the event that any changes in the future design or <br />location of the building are planned, the conclusions and recommen- <br />dations'contained in this report shall not be considered valid <br />unless the changes are reviewed and conclusions of this report are <br />modified or verified in writing. It is recommended that the <br />geotechnical engineer be provided the opportunity for a general <br />review of the final project design and specifications in order that <br />the earthwork and foundation recommendations may be properly <br />interpreted and implemented in the design and specifications. <br />This report does not provide earthwork specifications. We can <br />provide guidelines for your use in preparing project specific <br />earthwork specifications. Please contact us if you need these for <br />your project. <br />This report presents both suggestions and recommendations. The <br />suggestions are presented so that the owner and the owner's <br />representatives may compare the cost to the potential risk or <br />benefit for the suggested procedures. <br />11 <br /> <br />lambert ana ~,s~sociates <br />CONSULTmG GEOTECNwUL ENG~N EE RS AND <br />MATERIAL iESTIHG ~ <br />
The URL can be used to link to this page
Your browser does not support the video tag.