<br />GENERAL NOTES
<br />(APPLIES TO ALL SHEETS)
<br />1. THE INFORMATION SHOWN ON THESE DRAWINGS CONCERNING TYPE AND LOCATION OF UNDERGROUND AND OTHER UTILITIES IS NOT GUARANTEED
<br />TO BE ACCURATE OR ALL INCLUSIVE. THE CONTRACTOR IS RESPONSIBLE FOR MAKING HIS OWN DETERMINATIONS AS TO THE TYPE AND
<br />LOCATION OF UNDERGROUND AND OTHER UTILITIES AS MAY BE NECESSARY TO AVOID DAMAGE THERETO. THE CONTRACTORS SHALL NOTIFY THE
<br />UTILITY COMPANIES IN ADVANCE OF THEIR CONSTRUCTION OPERATION TO ENABLE THEM TO FIELD LOCATE THEIR UTILITIES.
<br />2. THE CONTRACTOR SHALL VERIFY LOCATIONS OF ALL EXISTING UTILITIES AND REPORT FINDINGS TO THE LAFARGE PRIOR TO PROCEEDING WITH
<br />RELATED CONSTRUCTION. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO SATISFY HIMSELF THAT ALL EXISTING UTILITIES, WHETHER
<br />SHOWN ON THESE PLANS OR NOT, HAVE BEEN PROPERLY LOCATED. THE CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR THE PROTECTION
<br />OF UTILITIES AFFECTED BY THE PROSECUTION OF THIS CONTRACT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING THE AFFECTED
<br />UTILITY COMPANY AND THE COORDINATION OF ALL WORK IN THE PROXIMITY OF THE UTILITIES.
<br />3, IN ADVANCE OF NEW UTILITY CONSTRUCTION, THE CONTRACTOR IS REQUIRED TO POTHOLE ALL UTILITIES TO WHICH THE NEW UTILITIES ARE
<br />TO BE CONNECTED, AND ALL UTILITIES WHICH ARE GOING TO BE CROSSED, ONCE EXPOSED, THE CONTRACTOR SHALL VERIFY THE VERTICAL
<br />AND HORIZONTAL LOCATION OF ALL EXISTING UTILITIES. THE CONTRACTOR SHALL NOTIFY THE LAFARGE OF ANY DIFFERENCES BETWEEN ACTUAL
<br />LOCATIONS AND LOCATIONS GIVEN ON THESE PLANS. NO CONTRACTOR CLAIMS FOR EXTRA COMPENSATION WILL BE GRANTED FOR PROJECT
<br />DELAYS ASSOCIATED WITH REDESIGN NECESSITATED BY CHANGES IN ACTUAL LOCATIONS BASED ON FIELD VERIFICATION. IF THE CONTRACTOR
<br />HAS TO REDO CONSTRUCTION TO AVOID UTILITY CONFLICTS DUE TO HIS FAILURE TO POTHOLE EXISTING STRUCTURES IN ADVANCE OF NEW
<br />UTILITY CONSTRUCTION, NO EXTRA COMPENSATION WALL BE GRANTED.
<br />C THE CONTRACTOR SHALL BE RESPONSIBLE FOR RESTORING ALL SURFACES AND RELATED STRUCTURES SUCH AS DRIVEWAYS, CURBS, GUTTERS,
<br />WALKS, AND BITUMINOUS PAVEMENTS TO ORIGINAL CONDITIONS (OR BETTER) AND GRADES, UNLESS DESIGNATED OTHERWISE ON THE DRAWINGS.
<br />THE LAFARGE OR LAFARGE'S REPRESENTATIVE AND THE CONTRACTOR SHALL TOGETHER COORDINATE THE DOCUMENTATION OF EXISTING GRADES AND
<br />OTHER INFORMATION PRIOR TO ALL CONSTRUCTION ACTIVITIES.
<br />5. THE CONTRACTOR SHALL CONTACT THE UTILITY NOTIFICATION CENTER OF COLORADO (PHONE 1 -500- 922 -1987) FOR THE MARKING OF UNDERGROUND
<br />UTILITIES AT LEAST 48 HOURS PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL TAKE PRECAUTIONARY MEASURES TO PROTECT ALL UTILITY
<br />LINES SHOWN AND OTHER UTILITY LINES OTHERWISE LOCATED
<br />6. THE LAFARGE- DEVELOPER SHALL PROVIDE THE CONTRACTOR WITH A COMPLETE AND UPDATED SET OF ENGINEERING CONSTRUCTION DRAWINGS.
<br />THESE DRAWINGS, AND ANY REQUIRED PERMITS, SHALL BE AT THE PROJECT SITE AT ALL TIMES. IF NO PLANS APPEAR ON THE PROJECT SITE,
<br />CONSTRUCTION ACTIVITIES MAY BE HALTED AT THE DISCRETION OF THE LAFARGE.
<br />7, BEFORE WORK BEGINS, THE CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS AND MUST NOTIFY THE REQUIRED PARTIES AT LEAST 24 HOURS
<br />IN ADVANCE OF COMMENCING CONSTRUCTION ACTIVITIES.
<br />8. THE CONTRACTOR SHALL COMPLY WITH THE PROVISIONS OF THE ATSSA GUIDE FOR WORK AREA TKAFFIC CONTROL AND THE MANUAL OF UNIFORM
<br />TRAFFIC CONTROL DEVICES FOR CONSTRUCTION SIGNAGE.
<br />9. ALL SURPLUS MATERIAL, TOOLS, AND TEMPORARY STRUCTURES, FURNISHED BY THE CONTRACTOR, SHALL BE REMOVED FROM THE PROJECT SITE
<br />BY THE CONTRACTOR. ALL DEBRIS AND RUBBISH CAUSED BY THE OPERATIONS OF THE CONTRACTOR SHALL BE REMOVED, AND THE AREA
<br />OCCUPIED DURING CONSTRUCTION ACTIVITIES SHALL BE RESTORED TO ITS ORIGINAL CONDITION, WITHIN 48 HOURS OF PROJECT COMPLETION.
<br />10. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF INSTALLATION BETWEEN ALL UTILITIES, INCLUDING BUT NOT LIMITED TO WATER
<br />LINES, SPRINKLER LINES. UNDERDRAIN, STORM SEWER, SANITARY SEWER, TELEPHONE, ELECTRIC, SPRINKLER CONTROL WIRING, GAS, FIRE
<br />LINES, AND WATER AND SEWER SERVICE LINES. COORDINATION INCLUDES DETERMINING THE SCHEDULING OF WHICH UTILITIES ARE
<br />INSTALLED WHEN
<br />11. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE "DESIGN STANDARDS AND CONSTRUCTION SPECIFICATIONS" OF THE COLORADO
<br />DEPARTMENT OF TRANSPORTATION.
<br />12. ALL FILL AREAS AND SUBGRADES SHALL BE BACKFILLED AND COMPACTED TO A MINIMUM OF 95% OF MAXIMUM DENSITY, AS DETERMINED BY ASTM D698.
<br />EXISTING IN PLACE SOILS THAT ARE TO BE USED FOR SUBGRADE SHALL BE SCARIFIED TO A DEPTH OF 6" (INCHES) AND THEN SHALL BE RECOMPACTED
<br />TO THE ABOVE REFERENCED DENSITY. ALL EXISTING VEGETATION AND TOPSOIL MUST BE STRIPPED PRIOR TO SUBGRADE SCARIFICATION AND RECOMPACTION.
<br />13. ALL CONNECTIONS TO THE EXISTING DITCHES SHALL BE DONE IN A WAY SO AS TO MINIMIZE DISRUPTION IN SERVICE TO EXISTING USERS.
<br />14. ALL LENGTHS SHOWN ARE FROM CENTER TO CENTER OF STRUCTURES TO END OF FLARED END SECTIONS.
<br />15. THESE CIVIL DRAWINGS ARE BASED ON THE TOPOGRAPHIC SURVEY BY LAFARGE NORTH AMERICA, DATED OCTOBER 16, 2003. ADDITIONAL SURVEY
<br />INFORMATION IS BASED ON THE TOPOGRAPHIC SURVEY BY SCOTT, COX & ASSOCIATES, INC. DATED MARCH 8, 2004.
<br />16. EXISTING UTILITY AND ELEVATION INFORMATION WAS BASED ON INFORMATION PROVIDED BY LAFARGE NORTH AMERICA, FIELD VERIFICATION IS REQUIRED
<br />FOR ALL EXISTING UTILITIES AND &TIE FEATURES PRIOR TO CONSTRUCTION.
<br />17. CONCRETE USED FOR THE CHANNEL SHALL CONFORM TO THE FOLLOWING SPECIFICATIONS:
<br />A. COMPRESSIVE STRENGTH: MINIMUM 3,500 PSI COMPRESSIVE STRENGTH AT 28 DAYS.
<br />B. SHALL INCORPORATE THE USE OF SYNTHETIC FIBROUS CONCRETE REINFORCEMENT. SEE NOTE 18
<br />C. CEMENT: TYPE I OR II.
<br />D. FINE AGGREGATE: SAND CONFORMING TO ASTM C -33.
<br />E. COARSE AGGREGATE: CRUSHED GRAVEL CONFORMING TO ASTM C -33. MAXIMUM 3/4" SIZE.
<br />F. ENTRAINED AIR: 6% ( +/- 2R).
<br />G. WATER- CEMENT RATIO: 0.45 MAXIMUM.
<br />H. SLUMP: 4" TO 6".
<br />I. CHANNEL SHALL BE FORMED WITH DRESSED LUMBER OR PLYWOOD. THE CONTRACTOR MAY UTILIZE SLIP FORMS PER THE LAFARGE'S APPROVAL.
<br />J. ALL WORK SHALL BE IN ACCORDANCE WITH ACI 301 -89 'SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS" AND THE COLORADO
<br />DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS,
<br />18. FIBROUS CONCRETE REINFORCEMENT
<br />A. ACCEPTABLE PRODUCTS:
<br />1. FIBERMESH; FIBERMESH, INC.
<br />2. FORTA -CEP; FORTA CORP.
<br />3. APPROVED SUBSTITUTE
<br />B. MATERIAL: VIRGIN POLYPROPYLENE COLLATED FIBRILLATED FIBERS CONTAINING NO REPROCESSrD OLEFIN MATERIALS AND HAVE TENSILE STRENGTH OF
<br />NOT LESS THAN 70 KS;.
<br />C. FIBER LENGTH: PER MANUFACTURER'S RECOMMENDATIONS FOR THE APPLICABLE CONCRETE Mli.
<br />D. ADD FIBROUS CONCRETE REINFORCEMENT MATERIALS AT THE TIME CONCRETE IS BATCHED. AD) MINIMUM OF 1.5 LB. OF FIBER PER CUBIC YARD OF
<br />CONCRETE.
<br />E. MIX BATCHED CONCRETE IN STRICT ACCORDANCE WITH FIBROUS CONCRETE REINFORCEMENT MMUFACTURER'S INSTRUCTIONS.
<br />F. PLACE AND FINISH CONCRETE IN ACCORDANCE WITH THE FIBROUS CONCRETE REINFORCEMENT 4ANUFACTURER'S INSTRUCTIONS.
<br />19. CONCRETE MIX DESIGN AND FIBROUS REINFORCING SPECIFICATION SHALL BE SUBMITTED TO LAFAR3E FOR REVIEW AND APPROVAL PRIOR TO CONSTRUCTION.
<br />20, CONSTRUCTION OF THE PROPOSED CONCRETE LINED DITCH MAY BE ACCOMPLISHED DURING THE IPRIGATION SEASON (MARCH THROUGH NOVEMBER), AS
<br />LONG AS THE WORK DOES NOT NEGATIVELY AFFECT THE MAINTENANCE AND /OR OPERATIONS OF THE EXISTING SMITH & EMMONS DITCH. ANY WORK
<br />RELATED TO THE EXISTING DITCH, INCLUDING CONNECTIONS TO THE EXISTING DITCH, MOOIFICATIO16 TO THE EXISTING DIVERSION STRUCTURES
<br />AND FILLING OF THE EXISTING DITCH, WALL OCCUR DURING THE NON- IRRIGATION SEASON. THE LArARGE WILL TAKE ALL PRECAUTIONS TO ENSURE
<br />THAT WATER DELIVERY DURING THE IRRIGATION SEASON WILL NOT BE AFFECTED BY THIS WORK.
<br />FINAL ENGINEERING PLANS
<br />SMITH AND EMMONS IRRIGATION DITCH RELOCATION
<br />DUCKWORTH PIT
<br />WELD COUNTY, COLORADO
<br />PPE-PAWD FOR
<br />LAFARGE NORTH AMERICA
<br />UGHTHOUSE COVE LAKE\
<br />I�
<br />�I
<br />I
<br />I
<br />I
<br />I�
<br />II
<br />! i L- -
<br />STA 14 +00 TO 19 +62.4
<br />SHEET C3
<br />STA 8+25 TO 14 +00
<br />SHEET C2
<br />EXISTING LOCATION OF THE
<br />SMITH AND EMMONS DITCH
<br />PROPOSED ALIGNMENT OF THE
<br />SMITH AND EMMONS DITCH
<br />STA 1+00 TO 8 +25
<br />SHEET C2
<br />PROPOSED 60'
<br />DITCH EASEMENT
<br />I e 11 \ Ill , 1 I
<br />APPROXIMATELY *FLD COUNTY ROAD 20 1/2�
<br />2 112 MILES TO
<br />COUNTY LINE ROAD
<br />(WELD COUNTY ROAD 1)
<br />I
<br />J
<br />a
<br />Y
<br />\w
<br />Jw
<br />U
<br />10
<br />x
<br />a
<br />0
<br />- -
<br />,� 1
<br />�I
<br />I
<br />LOCATION PLAN
<br />SCALE: 1" =200'
<br />INDEX
<br />LEGEND
<br />(APPLIES TO ALL SHEETS)
<br />-40 PROPOSED CONTOUR
<br />(ADD 4800 TO ALL CONTOUR ELEVATIONS)
<br />s7�o EXISTING CONTOUR
<br />- -a POINT WHERE PROPOSED GRADE
<br />MEETS EXISTING GRADE
<br />X 49'5 PROPOSED SPOT ELEVATION
<br />(ADD 4800 TO ALL SPOT ELEVATIONS)
<br />.rttz EXISTING SPOT ELEVATION
<br />HISTORIC SHEET FLOW
<br />PROPOSED FLOW DIRECTION
<br />EXISTING TREES
<br />-w -w- EXISTING WATERLINE
<br />T T - EXISTING TELEPHONE LINE
<br />- Po Po- EXISTING OVERHEAD POWER LINE
<br />x -X- EXISTING FENCE
<br />PROPERTY LINE
<br />DO 02 -BH14
<br />EXISTING BORING INVESTIGATION "(-4 nnN
<br />D' EXISTING OVERHEAD POWEP F
<br />DETAIL NUMBER
<br />2 --
<br />4 5
<br />SHEET ON WHICH DETAIL IS NOTED �y �----- SHEET ON WHICH DE TAIL
<br />SECTION NUMBER
<br />SHEET ON WHICH SECTION IS NOTED -� 2 3
<br />III SHEET ON WHICH SECTION IS FOUND
<br />APPROXIMATELY
<br />1/4 MILE TO
<br />- WELD COUNTY ROAD 7
<br />�1\ i 7
<br />-Fl-
<br />TI TLE SHEET NO.
<br />Permit #: 3- Confidental ?:
<br />COVER SHEET Class: Type -Seq.:
<br />C 1 From: To
<br />Doc. Name:
<br />GRADING AND DRAINAGE PLANS C2 Doc. Date (if no date;tap) : an S
<br />STA 1 +00 TO 14 +00
<br />GRADING AND DRAINAGE PLAN, PROFILE AND DETAILS C3
<br />STA 14 +00 TO 19 +62.4 - - -- --
<br />��
<br />CIVIL DETAILS C4 SCOTT, COX & ASSOCIATES, INC.
<br />consulting engineers surveyors
<br />1530 55th Street Boulder, Colorado 80303
<br />(303) 444 - 3051
<br />DPA 1/09/04
<br />REVISED 1/16/04
<br />REVISED 5/5/04
<br />REVISED 5/16/04
<br />JOB N0. 03532 DWG NO. 03532 -3 SHEET C1
<br />
|