Laserfiche WebLink
• TABLE 83 <br />If ~' TEST NO.: 1, LA 264 <br />ZONE TESTED: Overburden <br />TYPE OF TEST: Pumping <br />L•lell LA 264 <br />l Total Depth-ft 297 <br />Oiam. of Bit-ft 0.50 <br />Diam, of Csg.-ft 0.34 <br />t Elev. of TOC-ft 7090 <br />` Depth to Static Water-ft 50.93 <br />1 Elev. of Static Water-ft 7039 <br />J Pumping Time-minutes 148. <br />Total Volume Pumped-ft3 283.7 <br />Remarks: Surface casing set at 30.9 ft. Four inch steel casing set at <br />297 ft. with bottom capped and perforated from 62 ft. to 276 <br />ft. Water was encountered at about 72 ft. during drilling. <br />Estimated discharge during drilling was 15 gpm. No noticeable <br />increase in discharge over the interval between 72 ft. and <br />297 ft. Pump was set at 80 ft. During first 5 minutes of <br />` test. pump discharge was throttled. Pump discharge was in- <br />creased to capacity at 6 minutes into the test. Thereafter <br />pump discharge remained constant xithin +1 percent at 1.99 <br />ft3/min. <br />1 Elapsed Time Drawdown <br />t, minutes s, ft <br />0 0 <br />0.95 0.88 <br />2.00 1.01 <br />5.02 1.26 <br />10.77 3.56 <br />14.27 4.30 <br />18.65 4.88 <br />25.03 5.55 <br />32.63 6.14 <br />~i <br />-/ <br />