<br />/45. The Division has no further concerns. BRL added the <br />information for the four culverts to the culvert table in a <br />revised page Exh-8-26. <br />./46. The Division has no further concerns. The annotation for the <br />culvert at the base of the gob pile was added to revised Map <br />20, Sedimentation Control Plan, and revised Map 21-1, Drainage <br />Plans. <br />" 47. The Division has no further concerns. Map 20, Sedimentation <br />Control Plan, was revised with an annotation for culvert C-F1. <br />,/48. The Division has no further concerns. On page Exh-8-23 the <br />VV operator stated that 6 fps was the threshold erosive velocity. <br />The operator's consultant noted the Division's position that <br />5 fps was a general guideline threshold velocity only. The <br />actual design erosive velocity would depend on soil type and <br />vegetation. <br />~ 49. The Division has no further concerns. The annotations for <br />ditches D-F1 and D-F2 were added to revised Map 20, <br />Sedimentation Control Plan. <br />/50. The Division has no further concerns. The information for the <br />five ditch designs was added to revised page Exh-8-24. <br />51. The Division requested small area exemption (SAE) designs for <br />the coal waste pile topsoil pile and the coverfill stockpile. <br />On behalf of BRL, WESTEC submitted revised pages and revised <br />Drawings 95266-02 and 95266-04 for Volume IV, which include <br />designs for the SAES. The topsoil stockpile covers .3 acres <br />and the coverfill stockpile covers 1.5 acres, BRL stated that <br />SAES were needed in these two cases, due to the topographic <br />restrictions in that general area. <br />Concerning the coal waste pile topsoil stockpile SAE, BRL has <br />decided not to put in an upland diversion ditch directly above <br />the stockpile. There is a haul road ditch upgradient of the <br />stockpile, but, due to the ditch's location, there still is a <br />.5 acre area that drains against the topsoil stockpile. This <br />area should be watched to see if an upland diversion ditch <br />immediately adjacent to the topsoil stockpile will be needed. <br />Concerning the coverfill stockpile, the revised calculation <br />worksheet, found in Appendix C, for the "temporary upland <br />diversion for coverfill" shows an input discharge of 26.80 <br />cfs. However, in Appendix B, the worksheet for the "upper <br />diversion of coverfill" for the 100 year-24 hour event shows <br />a peak discharge of 28.66 cfs. Please reconcile this <br />difference. <br />4 <br />