Laserfiche WebLink
• • ~ ~~~~~~ I~ III I IIII I II IIIII III <br />flit nartl D. Lamm <br />Governor <br />DEPARTMENT OF NATURAL RESOURCES <br />Davitl H Getches. Executive Duector <br />MINED LAND RECLAMATION DI\ <br />DAVID C. SHELTO N, Director <br />October 4, 1985 <br />Terrell Johnson <br />Colorado Yampa Coal Co. <br />29588 County Road 21 <br />Oak Creek, CO 80467 <br />RE: Interpretation of Hydrologic Monitoring at Mine #3 <br />File C-84-062 <br />Dear Mr. Johnson: <br />Attached is the Division's interpretation and results of the water sampling <br />that was conducted at the #3 mine on July 29 and 30, 1985. As with an~r <br />interpretation, you may view the results differently. At the end of this <br />letter, there are general comments on your monitoring ?ion for your <br />consideration. <br />1. Sample CYCC38507A is a partial parameter list surface water sample ta<=n <br />on upstream Foidel Creek at site 09243900. The ML.D sample had a pH and <br />EC of 8.17 and 1,970 umhos, respectively. This compares ro aata <br />collected in July 1984 by the operator of pH = 8.6 and ..C = 1,650 and in <br />August 1984 of pH - 8.3 and EC = 2,200. The samcies appear to be <br />consistent in relative composition and concentrations. <br />2. Sample CYCC38507B is a full parameter list sample of bedrock overburden <br />aquifer. The MLRD sample had an EC of 1320 umhos and iDS of 1,080 mg/l. <br />Since 1980, the operator has reported EC values from 1,000 tc 1,390 umhos <br />and TPS values from 804 mg/1 to 1,168 mg/1. The major discrepancy <br />between the MLRD and CYCC sample is in the EC. 'd'nen '1L.P0 in itially <br />sampled the well, the EC was 1,080 but increased to 1,320 as the Nell Nas <br />bailed to bring in fresh ground water. The fact tha~_ C(CC does not hail <br />wells may er.plain this discrepancy. <br />3. Sample CYCC38507C is a full list groundwater sample Oaken at the Middle <br />Creek Pit spoils well. The spoil water quality was high in sulfates at <br />2,510 mg/l, high in dissolved solids at 3,190 mg,l and~has ,i nigh C at <br />3,960 umhos. The mine #3 application predicted a spoil water quality of <br />2,200 mg/1 TDS and an EC of 3,000 umhos, basea on leach tests. The <br />sample results show that the spoils water quality is ar_tualiy worse than <br />was predicted. No data has been supplied to MLRD by C'(CC on this well to <br />date to enable a comparison. <br />a23 Centennial Building, tat 3 Sherman Street Denver, Colorado 90203 Tel. (303) 866-3567 <br />