Laserfiche WebLink
N'+ <br />is 4 id I N I N G (Continued).. <br />!, ~ ; ~. <br />~I~~~ <br />• <br />The cable is of steel wire 3~4ths of an in. and in good condition. <br />j <br />. ~ <br />~'~,I <br />Cable hes been in use four months. Hook uaed on end of eable• <br />i~ <br />~,: ~ <br />Icy <br />' <br />chain hook,the same has been in use four months. <br />' r.j There are no devices employed to prevent over-winding. idaterial <br />i ;. <br />~~~ is hoisted from one level. the bell line consists of 1~2 in. <br />L <br />~';!I <br />;',~ hemp rope and is in good condition. The stato code of signals <br />i~ <br />j ~~~,: is em lo•od the are osted in the e <br />P V ~ $ P ngine room~at collar of shaft <br />I t;i i~ <br />I ~'`! ' <br />I ~ '' <br />and at each level station. <br />w•~, A21 persons are prohibited from riding on loaded bucket this or- <br />Ly <br /> der is posted at collar of shaft. Notice stating tho~maximum <br /> <br />,I,~ <br />.~ number of men permitted to ride upon bucket at one time is not <br />~~ <br />~% posted at collar of shaft or at each 7eve1 station. <br />"1 All level stations are provided with passage way around working <br /> <br />.' <br />I <br />I `~' shaft. Shaft is at all tations <br />$ provided with guard rails. <br />' <br />• <br />f <br /> ~. The shaft is secured by pillar of ground upon each side sufficient <br />, <br /> . <br />~' ('~ to insure safety. All icinzes or mill holes are covered or sur- <br />' <br /> 1 <br />; <br /> i,,~;: rounded with guard rails~tho shaft is not being suvnk. <br /> '~ ' <br /> <br />,, <br />~!'~' The power houseis 75 ft west of shaft, <br />i <br /> ;y <br />' <br />! <br />~ ; <br />The method of ore extraction is drifiing with hand steel. <br />: <br />I , <br />~ '` Tho method of timbering is drift sets and sufficient. <br />~ <br /> ~ <br />~' <br /> ~~} j The timbers uaed are white spruce prepared at mill and in good <br /> <br /> ':' condition, Under ground tramming is done by manual labor with <br />~ <br />~ <br /> .~ <br />;,' bucket and truck, Trackage 18 in, gunge 9 lb rails, <br />!I~,'I <br />;; <br /> i„;iji Amount of water in gals dealt with 20 gals maximum <br />The a <br />atam <br />i , <br />y <br />' ~~ ' <br />~ <br />i em to ed electric <br />III P Y pump capacity of pump 50 gals per minuto, <br />! ;~', Ventillation is natural and sufficient. Noxious gases aro not met <br />! <br />~ <br />' <br /> <br />j '~ <br />~''~ f. Y <br />with. Sanitar conditions are good, The shaft is divided into <br />j~ <br />! ' ~' tmo compartments bucket way and man way, '.'lte man wa is <br />y provided <br /> with laddera~the ladders aro safe eocure and accessible, <br />~'. <br /> L';i' Ladder way contains water pipe, Landi s are <br />ng provided in ladder- <br />. ~' ~!~ way not to exceed 20 ft apart, There are no winzes or man ways <br />b <br /> <br />` "t'~~ connecting levels. The mine hr~s but one exit for employeea~afain ~ <br />~ <br />: ~ o enin onl The are drivi ~ <br />~~ P g Y Y ng a draft and will noon be connected ~ <br /> i I~ with another shaft. Lighting under ground electric <br />d <br /> an <br />candlos. <br />(, <br />_ _-- <br />