ORIGINAL - POBLIC FILE <br />(Page 2) <br />MINE ID # OR PROSPECTING ID #: nn_Iaan-gee <br />INSPECTION DATE: 5-~0-Od INSPECTORS INITIALS: ~~ <br />OBSERVATIONS <br />The Division conducted a monitoring and construction progress inspection of <br />the site on 5/20/04. Prior to the physical inspection of the site, a brief <br />discussion about the overall project and the pending technical revision for <br />the expansion of the East Cresson mine area was held, with Mr. Phil Barnes, <br />manger of environmental resources for the site. <br />Clay liner deployment and smooth grading of the Phase IVC leach pad <br />expansion area is continuing, no major problem noted. According to Mark <br />Tidquist.As resident engineer for the site, Poly Flex plans to start <br />deploying geomembrane liner as soon as possible. To facilitate and expedite <br />the clay liner deployment, Ames had stockpiled bentonite-amended clay along <br />the edge of the slopes to be lined. <br />Continued the inspection to the Phase V pregnant solution collection area <br />and recorded the following readings from the high and low volume solution <br />collection transducers. <br />High Volume solution collection transducer # 7 was recorded at 21.0 # 8 was <br />at 21.0 # 9 was at 21.4 and # 10 was at 21.8. Low volume transducer # 1 was <br />at 17.5 and 3 2 was at 7.8 inches of hydrostatic head. <br />Inspected the Phase II and I pad and pregnant solution collection areas and <br />recorded the following readings from the high and low volume solution <br />collection systems. <br />Phase I high volume solution collection transducer # 1 was recorded at 35.0 <br /># 2 was at 37.0 and # 3 was at 37.5. Low volume transducer # 1 was at .22 <br />and # 2 was at .34. Piezometer for the pond was at 37.3 feet <br />Phase II high volume solution collection transducer # 4 was at 37.9 # 5 was <br />at 32.8 and # 6 was at 39.7. Low volume transducer # 1 was at .13 and # 2 <br />was at .30. Piezometer for the pond was at 39.7 feet. <br />All readings are in feet of hydrostatic head unless other wise noted. <br />Inspected the external pond, it was holding some water, no major problem <br />noted. While in the area, recorded the following readings from the low <br />volume solution collection transducers, # 1 was recorded at 12.8 and # 2 <br />was at 9.2 inches of hydrostatic head. <br />Inspected the under drain area, the upper and lower ponds were holding a <br />small amount of water, below discharge. Both the south and 4 inches pipes <br />were discharging. A split sample from the North under drain was provided <br />and the sample was delivered to CDOH&E LAB the same day. No major problem <br />noted. <br />18. E Confacf Address <br />NAME: MR PHIL BARNES CC: <br />OPERATOR: CC&V <br />STREET: P.n_R(~X 191 <br />CITY/STATE/ZIP: vlcme c~ Rna~n <br />Harry Posey (e-mail) <br />cc. r CE <br />