Laserfiche WebLink
(Page 2) <br />MINE ID # OR PROSPECTING ID #: M-i9Rn-~aa <br />INSPECTION DATE: ~ n-n~-m INSPECTORS INITIALS: ~~ <br />The Division conducted a water sampling inspection from the under drain discharge pipes of the leach pad facility on 10- <br />03- Ol. Present during the sampling was Mr. Lawrence Meyers of CC&V. Both 24 inch pipes and the 4 inch pipe of the <br />under drain discharge structures were discharging at the time of the sampling. With a split to the operator, using Division <br />sampling 8 ounce treated bottles; the following samples were collected for WAD cyanide analysis. <br />NORTH UNDER DRAIN SOUTH UNDERDRAIN 4" PIPE (~ ) <br />PH 6.33 5.67 4.4 <br />TEMP. 8.7 DEGREE CELCIUS 7.1 7.5 <br />COND 1432 1899 1537 <br />DISSOLVED OXYGEN 6.2 4.9 5.7 <br />GPM 3.01 13 3.0 <br />While in the area the following readings were collected from the Phase I, & II area leach pad low and High <br />volume pregnant solution collection pump transducers. <br />HIGH VOLUME TRANCDUCERS PHASE I # 1 WAS NOT FUNCTIONING, # 2 17.7, # 4, 23.1 <br />LOW VOLUME TRANCDUCER # 1 WAS MEASURED AT .15 AND # 2 WAS AT .17 <br />High Volume transducer PASS II # 4 was measured at 15.6, # 5 at 22.4 and #6 at 26.4 <br />Low volume transducer #1 was measured at .12 #2 was at .22 <br />All measurements are feet of head. <br />The water samples that were collected were placed in ice and delivered to the CDOHBcE LAD, the same day. <br />I & E Contact Address <br />NAME: Scott Lewis <br />OPERATOR: _ CC&V <br />STREET: _ P.O BOX 191 <br />CrfY/STATE/ZIP: VICTOR CO RDR60 <br />JAMES STEVENS <br />cc: ^ CE <br />^ BL <br />^ FS <br />^ HW <br />^ HMWMD (CH) <br />^ SE <br />^ WQCD (CH) <br />^ OTHER <br />