My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSPEC25376
DRMS
>
Back File Migration
>
Inspection
>
INSPEC25376
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 9:24:57 PM
Creation date
11/18/2007 9:59:48 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1979187
IBM Index Class Name
Inspection
Doc Date
9/8/2006
Doc Name
Inspection report
From
DRMS
To
Morrow & Sons Inc.
Inspection Date
8/15/2006
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The Division may require submittal of SPCC plan details sufficient to calculate a reclamation <br />bond and review of the associated reclamation plan. <br />Mine Stte laapectlona: <br />As an inspection item, where ground water impacts from a loss of containment may be expected, <br />the mine site operator may need to demonstrate that any wntained waters in the spill <br />containment structure do not compromise the ability to store the design storm event. (A <br />Professional Engineer certification of an SPCC plan demonstrates containment capacity <br />requirements.) Removal of accumulated fluids from containment structures must be done in <br />accordance with applicable laws and regulations. The presence or absence of a containment <br />structure or, if applicable, an SPCC plan at a mine site should be an inspection item and so noted <br />in the inspection report. Double walled tanks/convault tanks do not need secondary containment, <br />as it is inherent in the design of the structure. Temporary or portable tanks must abide by <br />appropriate containment requirements and have adequate containment. It is recommended that <br />spill plan site maps be updated as part of the annual report to show the current location of the <br />tank(s). <br />The presence of a slurry wall or other canstructed barrier intended to result itt a lined reservoir at <br />a construction materials operation is an acceptable alternative to an approval SPCC plan or <br />facility. The Operator must provide the Office documentation that the Office of the State <br />Engineer has approved the constructed barrier in order for the Division to accept the barrier as an <br />alternative. <br />The WQCD should be copied on the inspection report if an SPCC plan or Materials Containment <br />Plan is not available for inspection and it is determined that such plan(s) may be required. <br />(Please see regulated quantities, above.) <br />It is recommended that site placement of the containment structure(s) prevent and/or protect <br />against the loss of the containment structure(s) due to debris or lamdslides, avalanches, or other <br />- - - -- reasonably anticipated events that could compromise the ability of the facility to contain a -- -- <br />controlled product spill. Guidance contained herein pertaining to site placement shall only apply <br />to structures constructed after the date this policy is adopted. For existing facilities where site <br />placement has the potential to compromise contaimnent, the operator may propose structural <br />improvements or operational procedures. The Division will determine on acase-by-case basis if <br />a permit revision is required for the proposed structural improvement(s) in order to prevent <br />and/or protect against the loss of the containment structure(s) due to debris or landslides, <br />avalanches, or other reasonably anticipated events that could compromise the ability of the <br />facility to contain a controlled product spill. <br />
The URL can be used to link to this page
Your browser does not support the video tag.