Laserfiche WebLink
`: <br />~~~ '' <br />(Page 2) <br />MII~ ID ~ OR PROSPECTING ID ~ 80-244 <br />INSPECTION DATE 4-27-95/4-28-95 INSPECTOR'S INITIALS HR JS <br />THE DIVISION CONDUCTED AN INSPECTION OF THE SITE ON 4-27-95.PRESENT DURING THE INSPECTION <br />WERE,MR.JOHN HARDAWAY AND MR.SCOTT WEINSTED OF CC@VG.THE INSPECTION BEGAN HITH A BRIEF OVER <br />VIEW OF THE PROJECT AT THE OFFICE. <br />THE PHYSICAL INSPECTION BEGAN AROUND THE PHASE I VALLEY HEAP LEACH AREA.MR. JOHN HARDAWAY <br />GAVE A BRIEF EXPLANATION OF THE LEAK COLLECTION SUMP AND SOLUTION APPLICATION APPRATUS.THE <br />LEAK COLLECTION PUMP MONITORING APPRATUS AND STATION WAS INSPECTED.OPERATOR GAVE A BRIEF <br />DESCRIPTION OF THE SET UP AND HOW IT WAS DESIGNED TO WORK.THE INSPECTION CONTINUED TO THE PAD <br />AREA WHERE OPERATOR POINTED OUT THE BARREN AND PREGNANT SOLUTIN CARRYING PIPES AND BRIEFLY <br />EXPLAINED HOW THE SOLUTIONS ARE APPLIED TO THE PAD AND BACK TO THE PROCESSING PLANT. <br />INSPECTED THE UNDERDRAIN DISCHARGE AREA.THE 24"PERFORATED PIPE WAS DISCHARGING AT APPX. 3GPH <br />AT THE TIME OF THE INSPECTION. <br />INSPECTED LDS~1[LEAK DETECTION SUMP~1] IT WAS DRY.INSPECTED LDSf3 SUMP IT WAS HOLDING SOME <br />WATER.OPERATOR STATED THAT IT WAS BEING PUMPED DAILY ON TOP OF THE CARLTON TAILINGS.OPERATOR <br />WAS NOTIFIED THAT A SAMPLE WILL BE TAKEN FOR CYANIDE ANALYSIS TOMORROW MORNING BEFORE IT IS <br />PUMPED OUT IN THE MORNING. <br />INSPECTED THE GLOBE HILL PIT.IT HAS BEEN BACKFILLED APPX.3/4 OF THE WAY WITH IRON CLAD <br />OVERBURDEN AS APPROVED BY THE DIVISION.NO PROBLEM NOTED.INSPECTED THE IRON CLAD PIT.IT WAS <br />BEING BACKFILLED WITH CRESSON OVERBURDEN AT THE TIME OF THE INSPECTION. <br />INSPECTED THE STARTER PIT FOR THE CRESSON OPERATION.IT WAS BEING MINED AT THE TIME OF THE <br />INSPECTION.OPERATOR GAVE A BRIEF OVERVIEW OF YHE MINING PLAN. <br />INSPECTED THE PRIMARY AND SECONDARY CRUSHERS.AN OVERVIEW OF THE CRUSHER OPERATION WAS <br />PRESENTED BY THE OPERATOR AND A TOUR OF THE CONTROL AREA WAS CONDUCTED. <br />ON APRIL 28,1995 AT APPX.6:20A.M.FIVE WATER SAMPLES WERE COLLECTED FOR WAD AND TOTAL CYANIDE <br />ANALYSIS.TWO SAMPLE BOTTLES WERE COLLECTED FROM LEAK DETECTION SUMP /3.ONE SAMPLE BOTTLE FROM <br />LEAK DETECTION SUMP/SAND ANOTHER BOTTLE FROM THE 24"PERFORATED UNDERDRAIN PIPE.THE UNDERDRAIN <br />PIPE WAS DISCHARGING AT APPX.B GPM.OPERATOR WAS OFFERED A SPLIT BUT ONLY WANTED A SPLIT FROM <br />THE UNDERDRAIN DISCHARGE AND A SPLIT WAS PROVIDED. <br />I 6 E Contact Addreae <br />NAME 3O("(N.I"(II~*W~Y <br />OPERATOR C~ ~ ~ G' <br />STREET P' ~ ' SOX l°1 <br />CITY/STATE/ZIP ~(( (.,'~'~Q~ (_(~ D~ O~ <br />cc: JAMES STEVENS <br />^ CE <br />^ BL <br />^ FS <br />^ HW <br />^ HMWMD (CH) <br />^ SE <br />WQCD ( CH ) QAnT N t"1" ,S CN <br />^ OTHER CL Q N ¢ E <br />~30o cN7EYRV cRerK <br />D~~vE soulrl <br />ilt~t v cR~ L,0 <br />~o2.d~- ~ S 30 <br />