Laserfiche WebLink
CLIENT: Dames & Moore <br />Work Order: 98-5112 QC SUMMARY REPORT~- <br />Projcct: B&B Laboratory Control Spike -generic <br />Toluene 47.47 10 50 ND ~ 94.9°b 86.51 125.04 ............................................................. <br />1,1,1-Trichbrcelhane 40.97 15 50 ND 81.9% 84.35 122.06 ............................................................. <br />1,1,2-Trichloroethane 53.65 15 50 ND 107.3% 77.14 136.9 ............................................................. <br />Trichloroelhene 48.32 15 50 ND 96.6% 73.09 130.19 ............................................................. <br />Ynyl acetate 33.t2 15 50 ND 66.2% 63.82 138.29 ............................................................. <br />Ynyl chloride 38.32 15 50 ND 76.6% 36.91 137.99 ............................................................. <br />Total Xylene 49.78 75 50 ND 99.6% 81.96 126.79 ............................................................. <br />1,2-Dichloroelhane-d4 (SS-1) 46.fi6 0 50 ND 93.3% 75 110 ............................................................. <br />Toluene-d8 (SS-2) 48.24 0 50 ND 96.5% 82 126 ............................................................. <br />4Bromofluorobenzene (SS-3) 47.9 0 60 ND 96.8% 74 116 ............................................................. <br />S <br />s <br /> <br />QuaWlen: <br />ND -Nat Detected at the Reporting Limit <br />1- Analyse detected below quantization limio <br />E - Analyle detected above calibration limits S -Spike Recovery outside accepted recovery limila <br />B - Analyse detected in the aatociated Method Blank R - RPD outside accepted recovery limits <br />1 oJ2 <br />