III. Comments - Compliance <br />Below are Comments on the inspection. The comments include discussion of <br />observations made during the inspection. Comments also describe any <br />enforcement actions taken during the inspection and the facts or evidence <br />supporting the enforcement action. <br />to direct water from the West Pit into the pond, and water from the unnamed <br />drainage into Magpie Creek. Rip-rap still needed to be installed on the <br />corner and at inlets and outlets of the culvert. There is only a 3' 1 3/4" <br />drop in the 300' between the intersection of the two drainages and the <br />culvert, or a 1% grade. This diversion has a shallow gradient and high <br />potential for deposition. <br />Mr. Gomez had trenched through the Magpie Creek diversion embankment to <br />install a 48', 30" culvert. This culvert was a little shorter than required <br />but careful grading and the installation of rock energy dissapators on the <br />inlet and outlet should prove satisfactory. The embankment slope on the <br />outlet was 20%. Discussions were had on compaction around the culvert. <br />Culvert installation had proceeded nicely and was well on its way. <br />