My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2025-11-14_PERMIT FILE - M2025056 (29)
DRMS
>
Day Forward
>
Permit File
>
Minerals
>
M2025056
>
2025-11-14_PERMIT FILE - M2025056 (29)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2025 9:53:42 AM
Creation date
11/20/2025 8:29:28 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M2025056
IBM Index Class Name
Permit File
Doc Date
11/14/2025
Doc Name Note
Attachment 2 Material Safety Data Sheets
Doc Name
Application
From
Highbury Resources Inc
To
DRMS
Email Name
DMC
THM
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAFETY DATA SHEET <br /> G'LOL Diesel Fuel <br /> • <br /> reduce the possibility of static-initiated fire or explosion. Follow precautions to prevent static initiated fire. <br /> Use good personal hygiene practices.Use only with protective equipment specified in Section 8. Avoid repeated and/or <br /> prolonged skin exposure.Use only outdoors or in well ventilated areas. Wash hands before eating,drinking,smoking,or using <br /> toilet facilities.Do not use as a cleaning solvent on the skin.Do not use solvents or harsh abrasive skin cleaners for washing this <br /> product from exposed skin areas.Waterless hand cleaners are effective.Promptly remove contaminated clothing and launder <br /> before reuse.Use care when laundering to prevent the formation of flammable vapors which could ignite via washer or dryer. <br /> Consider the need to discard contaminated leather shoes and gloves. Emergency eye wash capability should be available in the <br /> near proximity to operations presenting a potential splash exposure. <br /> Special slow load procedures for"switch loading"must be followed to avoid the static ignition hazard that can exist when <br /> higher flash point material(such as fuel oil)is loaded into tanks previously containing low flash point products(such as this <br /> product)-see API RP 2003,"Protection Against Ignitions Arising Out Of Static,Lightning and Stray Currents." <br /> Storage <br /> Large quantities of diesel fuel are stored in tanks or portable containers at an ambient storage temperature. Separate from <br /> incompatible chemicals(Refer to Section 10)by distance or secondary containment. Keep away from flame,sparks,excessive <br /> temperatures and open flame. Use approved vented containers that are clearly labeled. Label all secondary containers that <br /> this material is transferred into with the chemical name and associated hazard(s). Empty product containers or vessels may <br /> contain flammable vapors.Do not pressurize,cut,heat,weld or expose such containers to sources of ignition. <br /> Storage tanks should have a venting system. If stored in small containers,the area should be well ventilated,away from <br /> ignition sources and protected from potential damage or vehicular traffic. Post"No Smoking"signs in product storage areas. <br /> This storage area should comply with NFPA 30"Flammable and Combustible Liquid Code"or applicable building code. The <br /> cleaning of tanks previously containing this product should follow API Recommended Practice(RP)2013"Cleaning Mobile Tanks <br /> in Flammable and Combustible Liquid Service"and API RP 2015"Safe Entry and Cleaning of Petroleum Storage Tanks". <br /> Incompatibles <br /> Keep away from strong oxidizers,ignition sources and heat. <br /> • <br /> 8. EXPOSURE CONTROLS / PERSONAL PROTECTION <br /> Occupational Exposure Limits <br /> Component CAS# List Value <br /> Diesel Fuel 68476-34-6 ACGIH TLV-TWA 100 mg/m3* <br /> Naphthalene 91-20-3 ACGIH TLV-TWA 10 ppm <br /> OSHA PEL 10 ppm <br /> ACGIH STEL 15 ppm <br /> *Critical effects;Skin;A3;CNS impairment. <br /> Engineering Controls <br /> Use adequate ventilation to keep vapor concentrations of this product below occupational exposure and flammability limits, <br /> particularly in confined spaces. Intrinsically safe equipment and non-sparking tools shall be used in circumstances where <br /> concentrations may exceed lower flammable limits. Grounding and bonding shall be used to prevent accumulation and <br /> discharge of static electricity.Emergency shower and eyewash should be provided in proximity to handling areas in the event of <br /> exposure to decontaminate. <br /> Personal Protective Equipment <br /> Exposure Equipment <br /> Eye/Face Wear appropriate chemical protective glasses or goggles or face shields to prevent skin and eye contact <br /> especially caused from splashing. <br /> Skin Wear appropriate personal protective clothing to prevent skin contact. Gloves constructed of nitrite, <br /> neoprene or PVC are recommended when handling this material.Chemical protective clothing such as of E.I. <br /> DuPont TyChem®,Saranex®or equivalent recommended based on degree of exposure.Note:The resistance <br /> of specific material may vary from product to product as well as with degree of exposure. <br /> S <br /> Page 5 of 11 May 2016 <br />
The URL can be used to link to this page
Your browser does not support the video tag.