Laserfiche WebLink
RULE 4 PERFORMANCE STANDARDS <br /> <br />South Taylor – Rule 4, Page 7 Revision Date: 7/21/25 <br /> Revision No.: MR-267 <br /> <br /> <br />foundations located along the ridge between Wilson and Taylor Creeks. Copies of the surveys are included in <br />Exhibit 14, Item 4. <br /> <br />4.09 DISPOSAL OF EXCESS SPOIL <br /> <br />Spoil removed from the South Taylor pit will be stockpiled as shown on Maps 45 and 20B. Colowyo expects <br />a 20% swell of excavated materials; therefore, part of the material stockpiled in the East and West Taylor Fills <br />will remain at the conclusion of the project as shown on Map 19. Placement will occur as described in <br />previous sections of this volume and in Volume 1. <br /> <br />Design of the two (East Taylor and West Taylor) fills associated with the South Taylor Mine plan are <br />provided in Exhibit 21. The East Taylor Fill will contain approximately 26.6 million yards of temporary out- <br />of-pit spoil and approximately 7.5 million yards of permanent out-of-pit spoil. The West Taylor Fill will <br />contain approximately 10.9 million yards of temporary out-of-pit spoil and approximately 22.6 million yards <br />of permanent out-of-pit spoil. Both fills will be regraded in accordance with the approved post mine <br />topography shown on Map 19. The final configuration of the fills is designed to minimize erosion. This <br />takes into account a number of the components of the other fill piles at the mine, which have proven <br />successful. The final outslope will not exceed 3h:1v. <br /> <br />Fill Name Temporary Volume Permanent Volume <br />East Taylor Fill 26,663,608 Cubic Yards 7,511,137 Cubic Yards <br />West Taylor Fill 10,993,667 Cubic Yards 22,609,016 Cubic Yards <br /> <br />Designed terrace ditches will be constructed at approximately 100 foot vertical increments. Terrace ditches <br />will be backsloped to direct runoff against the face to prevent flows from overflowing the edge of the ditch. <br />These terrace ditches will direct surface runoff perpendicular to the face into a permanent drainage channel <br />designed to pass safely the runoff from a 100 year, 24 hour precipitation event. Terrace ditches are shown on <br />Map 12 and design information is provided in Exhibit 7, Item 20, Parts A and B. <br /> <br />Reclamation, specifically topsoil replacement, seeding etc. will be implemented consistent with the Section <br />2.05 of the permit. <br />CONSTRUCTION PLAN <br />All available topsoil will be removed and either stockpiled for later use or direct haul replaced to a reclaimed <br />area. <br />Due to the fact that the valley fill locations are in close proximity to the initial boxcut area means the entire <br />footprint of these fills must be stripped of topsoil. As described in further detail in this submittal under <br />Section 2.05.3(1); “The entire seam sequence from the top overburden through to the bottom G8 seam, which <br />resides in the area of the initial boxcut, will be placed in the valley fill locations; this will allow Colowyo <br />enough spoil room to reach the desired mining depth.” <br />It is anticipated the valley fill drains and associated lateral drains will be constructed as one project during the <br />first two years of operation in the South Taylor operation for practical purposes and as a necessary step in <br />preparation of the area for full scale mining. <br />Channels constructed along the outside of the valley fills (perimeter relief drains) will be built immediately <br />after the logical completion of each terrace ditch across the faces of the fills, which obviously cannot be