Laserfiche WebLink
Exhibit 7 Page 8 Revision Date: 4/9/25 <br /> Revision No.: MR-261 <br />adequate freeboard to prevent overtopping were also evaluated. The TR-60 discharge criteria used in the <br />emergency spillway capacity and freeboard evaluations are as follows: <br /> <br /> Discharge flow basis for emergency spillway capacity evaluation (for a Class B pond): <br /> 100-yr, 6-hr peak flow + 0.12 (PMP, 6-hr peak flow - 100-yr, 6-hr peak flow) <br /> Discharge flow basis for impoundment freeboard evaluation (for a Class B pond): <br /> 100-yr, 6-hr peak flow + 0.4 (PMP, 6-hr peak flow - 100-yr, 6-hr peak flow) <br /> <br />TABLE 5 <br />IMPOUNDMENT HAZARD ANALYSIS SUMMARY <br /> <br />IMPOUNDMENT <br /> <br /> <br /> <br />HAZARD <br />CLASSIFICATION/BASI <br />S <br /> <br />SPILLWAY <br />CAPACITY <br />EVALUATION <br />BASIS1/RESUL <br />T <br /> <br />FREEBOARD <br />EVALUATION <br />BASIS1/RESULT/ <br />FREEBOARD <br />Work Area Pond A/Agricultural Land Class B/Ok Class B/Ok/1.55’ <br />Gossard Pond A/Agricultural Land Class B/Ok Class B/Ok/6.46’ <br />Stoker Siding Pond A/Agricultural Land Class B/Ok Class B/Ok/3.64’ <br />Rail Loop Pond A/Agricultural Land Class B/Ok Class B/Ok/1.82’ <br />Prospect Pond B/Proximity to State <br />Highway 13 <br />Class B/Ok Class B/Ok/0.61’ <br />West Pit Pond A/Agricultural Land Class B/Ok Class B/Ok/2.47’ <br />Section 16 Pond B/Proximity to State <br />Highway 13 <br />Class B/Ok Class B/Ok/0.96’ <br />East Taylor Pond A/Agricultural Land Class B/Ok Class B/Ok/0.76’ <br />Taylor Pump <br />Holding Pond <br />A/Agricultural Land Class B/Ok Class B/Ok/0.91’ <br />Notes: 1 Spillway capacity and freeboard for all ponds were evaluated for a uniform worst-case <br /> hazard classification (Class B) <br /> <br />The results of the WWC impoundment hazard analysis indicate that emergency spillway capacities and <br />available freeboard for all existing ponds are adequate to affect full compliance with applicable <br />requirements under the guidelines of TR-60, based on the applicable hazard classifications. Given this <br />confirmation of compliance, no modifications to the existing emergency spillway structures are required. <br /> <br />5.0 POND DESIGN EVALUATION RESULTS <br />The supporting SEDCADTM4 analyses and watershed maps are presented as attachments in each of the <br />individual pond design sections