Laserfiche WebLink
ACZ Laboratories, Inc. Inorganic Extended <br /> 2773 Downhill Drive Steamboat Springs, CO 80487 (800)334-5493 Qualifier Report <br /> Thorin Resources ACZ Project ID: L86570 <br /> ACZ ID WORKNUM PARAMETER METHOD QUAL DESCRIPTION <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG586576 Molybdenum(1312) M6020B ICP-MS RD For a solid matrix,the duplicate RPD(spike or matrix) <br /> exceeded the control limit,which is attributable to the non- <br /> homogeneity of the sample. <br /> Nickel(1312) M6020B ICP-MS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG586123 Nitrate/Nitrite as N(1312-DI) EPA 353.2-Automated HD Analysis is outside the intended scope of the method,which <br /> Cadmium Reduction does not provide hold time information for soil extracts. No <br /> hold time is observed for collection to extraction. The <br /> referenced method hold time is observed for extraction-to- <br /> analysis. <br /> EPA 353.2-Automated 06 Sample was received above recommended temperature. <br /> Cadmium Reduction <br /> Nitrite as N(1312-DI) EPA 353.2-Automated HD Analysis is outside the intended scope of the method,which <br /> Cadmium Reduction does not provide hold time information for soil extracts. No <br /> hold time is observed for collection to extraction. The <br /> referenced method hold time is observed for extraction-to- <br /> analysis. <br /> EPA 353.2-Automated Q6 Sample was received above recommended temperature. <br /> Cadmium Reduction <br /> EPA 353.2-Automated RA Relative Percent Difference(RPD)was not used for data <br /> Cadmium Reduction validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG586679 Nitrogen,ammonia(1312-DI) M350.1 Auto Salicylate w/gas Q6 Sample was received above recommended temperature. <br /> diffusion <br /> M350.1 Auto Salicylate w/gas RA Relative Percent Difference(RPD)was not used for data <br /> diffusion validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG586125 Phosphorus,ortho dissolved(1312-D1) M365.1-Automated Ascorbic RA Relative Percent Difference(RPD)was not used for data <br /> Acid validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG586398 Phosphorus,Total(1312-DI) M365.1-Auto Ascorbic Acid RA Relative Percent Difference(RPD)was not used for data <br /> (digest) validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG586211 Potassium(1312) M6010D ICP RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG586253 Residue,Filterable(TDS)@180C(1312) SM 2540 C-2011 RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG586424 Residue,Non-Filter(TSS)@180C(1312-SM 2540 0-2011/2015 BF Target analyte in prep/method blank at or above the <br /> DI) acceptance criteria. Target analyte was not detected in the <br /> sample[<MDL]. <br /> SM 2540 0-2011/2015 DJ Sample dilution required due to insufficient sample. <br /> SM 2540 D-2011/2015 RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> SM 2540 D-2011/2015 Z3 Sample volume yielded a residue less than 2.5 mg <br /> WG586576 Selenium(1312) M6020B ICP-MS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> Silver(1312) M6020B ICP-MS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG586211 Sodium(1312) M601013 ICP RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> Strontium(1312) M60100 ICP ZG The ICP or ICP-MS Serial Dilution was not used for data <br /> validation because the sample concentration was less than <br /> 50 times the MDL. <br /> WG586304 Sulfate(1312-01) M300.0-Ion Chromatography HD Analysis is outside the intended scope of the method,which <br /> does not provide hold time information for soil extracts. No <br /> hold time is observed for collection to extraction. The <br /> referenced method hold time is observed for extraction-to- <br /> analysis. <br /> REPAD.15.06.05.01 <br /> L86570-2404031336 Page 27 of 38 <br />