Laserfiche WebLink
ACZ Laboratories, Inc. Inorganic Extended <br /> 2773 Downhill Drive Steamboat Springs, CO 80487 (800)334-5493 Qualifier Report <br /> Thorin Resources ACZ Project ID: L86570 <br /> ACZ ID WORKNUM PARAMETER METHOD QUAL DESCRIPTION <br /> L86570-01 VVG586211 Aluminum(1312) M6010D ICP RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> M60100 ICP ZG The ICP or ICP-MS Serial Dilution was not used for data <br /> validation because the sample concentration was less than <br /> 50 times the MDL. <br /> WG586576 Beryllium(1312) M6020B ICP-MS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG586499 Bicarbonate as CaCO3 SM 2320 B-2011 06 Sample was received above recommended temperature. <br /> WG586211 Boron(1312) M6010D ICP RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG586304 Bromide(1312-DI) M300.0-Ion Chromatography M2 Matrix spike recovery was low,the recovery of the <br /> associated control sample(LCS or LFB)was acceptable. <br /> M300.0-Ion Chromatography RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG586576 Cadmium(1312) M6020B ICP-MS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG586623 Carbon,total organic(TOC)(1312-DI) SM 5310 B-2011/2014 HD Analysis is outside the intended scope of the method,which <br /> does not provide hold time information for soil extracts. No <br /> hold time is observed for collection to extraction. The <br /> referenced method hold time is observed for extraction-to- <br /> analysis. <br /> SM 5310 13-2011/2014 06 Sample was received above recommended temperature. <br /> SM 5310 B-2011/2014 RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG586499 Carbonate as CaCO3 SM 2320 B-2011 06 Sample was received above recommended temperature. <br /> WG586304 Chloride(1312-DI) M300.0•Ion Chromatography HD Analysis is outside the intended scope of the method,which <br /> does not provide hold time information for soil extracts. No <br /> hold time is observed for collection to extraction. The <br /> referenced method hold time is observed for extraction-to- <br /> analysis. <br /> M300.0-Ion Chromatography RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG586576 Chromium(1312) M60208 ICP-MS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> Cobalt(1312) M60208 ICP-MS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG586499 Conductivity©25C(1312-DI) SM 2510 B-2011 Q6 Sample was received above recommended temperature. <br /> WG586646 Copper(1312) M6020B ICP-MS RD For a solid matrix,the duplicate RPD(spike or matrix) <br /> exceeded the control limit,which is attributable to the non- <br /> homogeneity of the sample. <br /> W0586467 Fluoride(1312 DI) SM 4500-F C-2011 RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG586499 Hydroxide as CaCO3 SM 2320 B-2011 Q6 Sample was received above recommended temperature. <br /> WG586211 Iron(1312) M60100 ICP RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> Lithium(1312) M6010D ICP RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> Magnesium(1312) M6010D ICP RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG586206 Mercury(1312) M7470A CVAA Q6 Sample was received above recommended temperature. <br /> M7470A CVAA RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> REPAD.15.06.05.01 <br /> L86570-2404031336 Page 23 of 38 <br />