My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2024-06-10_REVISION - M2012032
DRMS
>
Day Forward
>
Revision
>
Minerals
>
M2012032
>
2024-06-10_REVISION - M2012032
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/11/2024 9:01:01 AM
Creation date
6/11/2024 8:58:23 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M2012032
IBM Index Class Name
Revision
Doc Date
6/10/2024
Doc Name
Request for Technical Revision
From
Thorin Resources, LLC
To
DRMS
Type & Sequence
TR17
Email Name
LJW
THM
EL1
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
100
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ACZ Laboratories, Inc. Inorganic Extended <br /> 2773 Downhill Dnve Steamboat Springs, CO 80487 (800)334-5493 Qualifier Report <br /> Thorin Resources ACZ Project ID: L86570 <br /> ACZ ID WORKNUM PARAMETER METHOD QUAL'DESCRIPTION <br /> L86570-01 VVG586211 Aluminum(1312) M6010D ICP RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> M60100 ICP ZG The ICP or ICP-MS Serial Dilution was not used for data <br /> validation because the sample concentration was less than <br /> 50 times the MOL. <br /> WG586576 Beryllium(1312) M6020B ICP-MS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG586499 Bicarbonate as CaCO3 SM 2320 B-2011 Q6 Sample was received above recommended temperature. <br /> WG586211 Boron(1312) M6010D ICP RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG586304 Bromide(1312-DI) M300.0-Ion Chromatography M2 Matrix spike recovery was low,the recovery of the <br /> associated control sample(LCS or LFB)was acceptable. <br /> M300.0-Ion Chromatography RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG586576 Cadmium(1312) M6020B ICP-MS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG586623 Carbon,total organic(TOC)(1312-DI) SM 5310 B-2011/2014 HD Analysis is outside the intended scope of the method,which <br /> does not provide hold time information for soil extracts. No <br /> hold time is observed for collection to extraction. The <br /> referenced method hold time is observed for extraction-to- <br /> analysis. <br /> SM 5310 B-2011/2014 06 Sample was received above recommended temperature. <br /> SM 5310 B-2011/2014 RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG586499 Carbonate as CaCO3 SM 2320 B-2011 06 Sample was received above recommended temperature. <br /> WG586304 Chloride(1312-DI) M300.0-Ion Chromatography HD Analysis is outside the intended scope of the method,which <br /> does not provide hold time information for soil extracts. No <br /> hold time is observed for collection to extraction. The <br /> referenced method hold time is observed for extraction-to- <br /> analysis. <br /> M300.0-Ion Chromatography RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG586576 Chromium(1312) M6020B ICP-MS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> Cobalt(1312) M6020B ICP-MS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MOL). <br /> WG586499 Conductivity @25C(1312-DI) SM 2510 B-2011 06 Sample was received above recommended temperature. <br /> WG586646 Copper(1312) M60206 ICP-MS RD For a solid matrix,the duplicate RPD(spike or matrix) <br /> exceeded the control limit,which is attnbutable to the non- <br /> homogeneity of the sample. <br /> WG586467 Fluoride(1312 DI) SM 4500-F C-2011 RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG586499 Hydroxide as CaCO3 SM 2320 B-2011 Q6 Sample was received above recommended temperature. <br /> W G586211 Iron(1312) M6010D ICP RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> Lithium(1312) M6010D ICP RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> Magnesium(1312) M6010D ICP RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG586206 Mercury(1312) M7470A CVAA 06 Sample was received above recommended temperature. <br /> M7470A CVAA RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> REPAD.15.06.05.01 <br /> L86570-2404031336 Page 23 of 38 <br />
The URL can be used to link to this page
Your browser does not support the video tag.