XS-East-400_StabiIity Wednesday, March 8, 2023 <br /> Number of Valid Surfaces: 7300 <br /> Number of Invalid Surfaces: 119 <br /> Error Codes <br /> Error Code -108 reported for 4 surfaces <br /> Error Code -111 reported for 115 surfaces <br /> Method: spencer <br /> Number of Valid Surfaces: 6796 <br /> Number of Invalid Surfaces: 623 <br /> Error Codes <br /> Error Code -108 reported for 7 surfaces <br /> Error Code -111 reported for 616 surfaces <br /> Method: g le/morgenstern-price <br /> Number of Valid Surfaces: 7232 <br /> Number of Invalid Surfaces: 187 <br /> Error Codes <br /> Error Code -108 reported for 5 surfaces <br /> Error Code -111 reported for 182 surfaces <br /> Error Code Descriptions <br /> The following errors were encountered during the computation: <br /> -108 = Total driving moment or total driving force < 0.1. This is to limit the calculation of extremely high <br /> safety factors if the driving force is very small (0.1 is an arbitrary number). <br /> -111 = Safety factor equation did not converge <br /> 12/12 <br />