Laserfiche WebLink
XS-North-600_StabiIity Wednesday, March 8, 2023 <br /> Number of Valid Surfaces: 6373 <br /> Number of Invalid Surfaces: 28 <br /> Error Codes <br /> Error Code -108 reported for 7 surfaces <br /> Error Code -111 reported for 21 surfaces <br /> Method: spencer <br /> Number of Valid Surfaces: 6292 <br /> Number of Invalid Surfaces: 109 <br /> Error Codes <br /> Error Code -108 reported for 7 surfaces <br /> Error Code -111 reported for 102 surfaces <br /> Method: g le/morgenstern-price <br /> Number of Valid Surfaces: 6332 <br /> Number of Invalid Surfaces: 69 <br /> Error Codes <br /> Error Code -108 reported for 7 surfaces <br /> Error Code -111 reported for 62 surfaces <br /> Error Code Descriptions <br /> The following errors were encountered during the computation: <br /> -108 = Total driving moment or total driving force < 0.1. This is to limit the calculation of extremely high <br /> safety factors if the driving force is very small (0.1 is an arbitrary number). <br /> -111 = Safety factor equation did not converge <br /> 12/12 <br />