Laserfiche WebLink
Geotechnical Stability Exhibit ��� <br /> Engineering Evaluation of Highwall Design for the South Quarry of the Morrison Quarry <br /> 4 Laboratory Testing <br /> Previous Testing <br /> Previous testing results from several firms, mostly performed by Advanced Terra Testing, Inc. of <br /> Lakewood, CO, was made available to HDR. Refer to the sections below for a summary of the <br /> performed laboratory testing, and refer to Appendix A, Subsurface Exploration Findings, for the <br /> full laboratory reports. <br /> listoric Strength Testing <br /> A total of seven (7) Uniaxial Compressive Strength (UCS) tests were performed on historic <br /> borings in accordance with ASTM D7012-14, Method D. Refer to Table 2 below for a summary <br /> of the testing results. <br /> Table 2 —Summary of Historic UCS Testing <br /> Unconfined <br /> Boring Depth Rock Type Compressive Strength <br /> (psi) <br /> M-2-18 43.0-43.5 Biotite Gneiss 20314 <br /> M-2-18 264.0-264.5 Granitic Gneiss 33012 <br /> M-3-18 303.7-304.5 Talc Gneiss 8386 <br /> M-3-18 337.0-337.5 Talc Gneiss 5321 <br /> M-4-18 173.0-174.0 Granitic Gneiss 9221 <br /> M-5-18 270.0-271.0 Biotite Gneiss 3601 <br /> M-5-18 305.0-306.0 Pegmatite 7658 <br /> Direct shear testing was performed on a total of 22 samples in accordance with ASTM D5607. <br /> Samples were tested using either natural fracture points or saw cuts, and with normal stresses <br /> approximately equivalent to in situ conditions. Refer to Table 3 below for a summary of the test <br /> results. <br /> May 2023 1 10 <br />