Laserfiche WebLink
Nix-Owens-Mon Water Quality No Southeastern To monitor the groundwater upgradient of the central portion of <br /> 4A &Water comer of site gravel pit.Can compare results to the downgradient station <br /> Elevation results to determine if any impacts to groundwater have <br /> occurred. <br /> Nix-Owens-Mon Water Quality Yes Western perimeter To monitor the groundwater downgradient of the gravel pit& <br /> 5A &Water of site. influence from nearby mining operations.Can compare results to <br /> Elevation the upgradient station results to determine if any impacts to <br /> groundwater have occurred <br /> Nix-RMCC-Mon 6 Water Quality Yes Western perimeter To monitor the groundwater downgradient of the gravel pit.Can <br /> &Water of site. compare results to the upgradient station results to determine if <br /> Elevation any impacts to groundwater have occurred <br /> Nix-RMCC-Mon 7 Water Quality No Eastern perimeter To monitor the groundwater upgradient of the mining operation. <br /> &Water of site. Can compare results to the downgradient station results to <br /> Elevation determine if any impacts to groundwater have occurred. <br /> Nix-RMCC-Mon 8 Water Quality No Northern perimeter To monitor the groundwater upgradient of the mining operation. <br /> &Water of site. Can compare results to the downgradient station results to <br /> Elevation determine if any impacts to groundwater have occurred. <br /> Nix-RMCC-Mon 9 Water Quality Yes Northwest comer of To monitor the groundwater downgradient of the gravel pit. <br /> &Water site. Installed in April 2023.Can compare results to the upgradient <br /> Elevation station results to determine if any impacts to groundwater have <br /> occurred. <br /> Piezo 13H-5B Water No North of Piezo BH- To establish groundwater flow direction,not used for water <br /> Elevation 5C,in cell 2. quality sample collection.Included in monthly water level <br /> sampling. <br /> Piezo BH-5C Water No Northwestern To establish groundwater flow direction,not used for water <br /> Elevation mining envelope,in quality sample collection.Included in monthly water level <br /> cell 2. sampling. <br /> Piezo BH-14 Water No On eastern site To establish groundwater flow direction,not used for water <br /> Elevation perimeter,in cell 2. quality sample collection.Included in monthly water level <br /> sampling. <br /> Piezo BH-21A Water No Central western To establish groundwater flow direction,not used for water <br /> Elevation perimeter,on quality sample collection.Included in monthly water level <br /> southern perimeter sampling. <br /> of cell 3. <br /> The following wells have been identified as the POC wells: Nix-Owens-Mon 5A, Nix- <br /> RMCC-Mon 6 and Nix-RMCC-Mon 9. Note: Nix-RMCC-Mon 9, in the northwest corner <br /> of the site, was installed in April 2023 at DRMS's request to provide data in the most <br /> downgradient point in that area of the permit. <br /> Wells Nix-Owens-Mon 2 and Nix-RMCC-Mon 6, located upstream and downstream, <br /> respectively, of the southwest mining envelope (including Cell 1, Cell 6, the proposed <br /> plant, siltation pond, and freshwater pond) will allow characterization of groundwater <br /> impacts of operations to the groundwater quality. Wells Nix-Owens-Mon 4A and Nix- <br /> Owens Mon 5A, located upstream and downstream of the southern mining envelop will <br /> allow determination of groundwater impacts from Cells 4 and 5. Similarly, wells Nix- <br /> RMCC-Mon 7 and Nix-RMCC-Mon 5A, located upstream and downstream of the <br /> northwestern mining envelope will allow determination of groundwater impacts across <br /> Cell 2 and Cell 3. Nix-RMCC-Mon 9 will be compared against Nix-RMMC-Mon 8 to <br /> evaluate influence across the northern perimeter of the site. Because Nix will use slurry <br /> walls, any water quality effects on groundwater are expected to be negligible. <br /> 9 <br />