Laserfiche WebLink
ACZ Laboratories, Inc. E;;1;111 <br /> 2773 Downhill Drive Steamboat Springs, CO 80487 (800)334-5493 <br /> JESA ACZ Project ID: L76600 <br /> NOTE:If the Rec%column is null,the highAow limits are in the same unds as the result. If the Rec%column is not null, then the high/low <br /> limits are in%Rec. <br /> Lead,potentially dissolved M200.8 ICP-MS <br /> ,ACZ ID Type Analyzed PCN/SCN 0C Sample round Units Rec% Lower Upper RPD Limit Qual <br /> WG553860 <br /> WG5538601CV ICV 10/28/22 20:35 MS220930-3 .05 .05153 mg/L 103 90 110 <br /> WG5538601CB ICB 10/28/22 20:37 U mg/L -0.00022 0.00022 <br /> WG55386OLFB LFB 10/28/22 20:39 MS221012-7 .0501 .04953 mg/L 99 85 115 <br /> WG553350PBW PBW 10/28/2220:40 U mg/L -0.0003 0.0003 <br /> WG553855PBW PBW 10/28/22 20:46 U mg/L -0.0003 0.0003 <br /> L76600-01AS AS 10/28/2220:52 MS221012-7 .0501 .00031 .05189 mg/L 103 70 130 <br /> L76600-01ASD ASD 10/28/22 20:54 MS221012-7 .0501 .00031 .0508 mg/L 101 70 130 2 20 <br /> Mercury,total M1631E,Atomic Fluorescence <br /> �ACZ ID Type Analyzed PCN/SCN QC Sample Found Units Rec% Lower Upper RPD Limit Qual <br /> WG541979 <br /> WG5419791CV1 ICV 05/11/2211:12 HG220325-4 10 10 ng/L 100 79 121 <br /> WG5419791CB1 ICB 05/11/2211.17 U ng/L -0.501 0.501 <br /> WG553078 <br /> WG553078CCV1 CCV 10/19/22 9:52 HG220913-4 10 10.4 ng/L 104 76.5 123.4 <br /> WG553078CCB1 CCB 10/19/22 9:57 U ng/L -0.501 0.501 <br /> WG553078PQV PQV 10/19/2210:01 HG220913-6 1 .9 ng/L 90 70 130 <br /> WG553078LFB LFB 10/19/2210:06 HG220913-5 2 1.75 n9/L 88 71 125 <br /> L76602-01MS MS 10/19/2210:20 HG220913-5 2 1.56 4.01 ng/L 123 71 125 <br /> L76602-01MSD MSD 10/19/2210:25 HG220913-5 2 1.56 3.96 ng/L 120 71 125 1 24 <br /> WG553078CCB2 CCB 10/1912210:40 U ng/L -0.501 0.501 <br /> WG553078CCV2 CCV 10/19/2210:49 HG220913-4 10 9.94 ng/L 99 76.5 123.4 <br /> WG553078CCB3 CCB 10/19/22 10:54 U ng/L -0501 0.501 <br /> WG553078CCV3 CCV 10/19/2211:46 HG220913-4 10 10.8 ng/L 108 76.5 123.4 <br /> WG553078CCB4 CCB 10/19/2211:51 U ng/L -0.501 0.501 <br /> WG553078CCV4 CCV 10/19/2212.29 HG220913-4 10 10.1 ng/L 101 76.5 123.4 <br /> WG553078CC85 CCB 10/19/2212.34 U ng/L -0.501 0.501 <br /> pH(lab) SM4500H+B <br /> ACZ ID Type Analyzed PCN/SCN QC Sample Found Units Rec*/ Lower Upper RPD Limit Qua[ <br /> WG553058 <br /> WG553058LCSW1 LCSW 10/18/2220:18 PCN65296 6 6 units 100 5.9 6.1 <br /> WG553058LCSW4 LCSW 10/18/2223:48 PCN65296 6 6 units 100 5.9 6.1 <br /> WG553058LCSW10 LCSW 10/19/226:37 PCN65296 6 6.1 units 102 5.9 6.1 <br /> WG553058LCSW13 LCSW 10119/2210:04 PCN65296 6 6 units 100 5.9 6.1 <br /> L76605-02DUP DUP 10/19/221151 7.1 71 units 0 20 <br /> WG553058LCSW16 LCSW 10/19/2211:55 PCN65296 6 6 units 100 5.9 6.1 <br /> Residue,Non-Filterable(TSS)@105C SM2540D <br /> IACZ ID Type Analyzed PCNISCN 0C Sample Found Units Rec*/, Lower Upper RPD Limit qual <br /> WG552719 <br /> WG552719PBW PBW 10/13/2212:15 U mall- -2 2 <br /> WG552719LCSW LCSW 10/13/2212:17 PCN623508 100 91 mg/L 91 80 120 <br /> L76600-01DUP DUP 10/13/2213:15 U U mg/L 0 10 RA <br /> L76600-2210311121 Page 5 of 12 <br />