My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2023-01-17_HYDROLOGY - M1977300
DRMS
>
Day Forward
>
Hydrology
>
Minerals
>
M1977300
>
2023-01-17_HYDROLOGY - M1977300
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/20/2023 12:57:44 AM
Creation date
1/19/2023 8:36:56 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1977300
IBM Index Class Name
Hydrology
Doc Date
1/17/2023
Doc Name
Water Monitoring - Groundwater and Surface Water
From
Colorado Legacy Land
To
DRMS
Annual Report Year
2022
Report Quarter_Month
Nov
Email Name
MAC
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AUZ Laboratories, Inc. • - - • - • <br /> 2773 Downhill Drive Steamboat Springs, CO 80487 (800)334-5493 - • • <br /> Ensero Solutions ACZ Project ID: L77063 <br /> METHODACZ ID WORKNUM PARAMETER QUAL DESCRIPTION <br /> L77063-01 WG554706 Cyanide,WAD SM4500-CN I,E-Colodmetric w/ RA Relative Percent Difference(RPD)was not used for data <br /> distillation validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> WG555033 Phosphorus,total M365 1-Auto Ascorbic Acid M1 Matrix spike recovery was high,the recovery of the <br /> (digest) associated control sample(LCS or LFB)was acceptable <br /> WG554602 Residue,Non-Filterable(TSS)@105C SW540D RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> SM2540D Z3 Sample volume yielded a residue less than 2 5 mg <br /> L77063-02 VVG554706 Cyanide,WAD SM4500-CN I,E-Colonmetric w/ RA Relative Percent Difference(RPD)was not used for data <br /> distillation validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> WG555033 Phosphorus,total M365.1-Auto Ascorbic Acid M1 Matrix spike recovery was high,the recovery of the <br /> (digest) associated control sample(LCS or LFB)was acceptable <br /> WG554602 Residue,Non-Filterable(TSS)@105C SM2540D RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> SM2540D Z3 Sample volume yielded a residue less than 2.5 mg <br /> REPAD.15.06.05.01 <br /> L77063-2301 1 01 51 5 Page 12 of 22 <br />
The URL can be used to link to this page
Your browser does not support the video tag.