Laserfiche WebLink
®% Trust our People.Trust our Data. p Billings,MT 800.735.4489•Casper,WY 888.235.0515 <br /> www.energylah.com Gillette,WY 866.686.7175•Helena,MT 177.472.0711 <br /> Work Order Receipt Checklist <br /> Energy Fuels Resources (USA) Inc C22080249 <br /> Login completed by: Kirsten L. Smith Date Received: 8/4/2022 <br /> Reviewed by: Chantel S. Johnson Received by: cml <br /> Reviewed Date: 8/5/2022 Carrier name: UPS <br /> Shipping container/cooler in good condition? Yes No ❑ Not Present ❑ <br /> Custody seals intact on all shipping container(s)/cooler(s)? Yes No ❑ Not Present ❑ <br /> Custody seals intact on all sample bottles? Yes ❑ No Ej Not Present 0 <br /> Chain of custody present? Yes 0 No ❑ <br /> Chain of custody signed when relinquished and received? Yes Z No ❑ <br /> Chain of custody agrees with sample labels? Yes Z No ❑ <br /> Samples in proper container/bottle? Yes 0 No ❑ <br /> Sample containers intact? Yes 0 No ❑ <br /> Sufficient sample volume for indicated test? Yes 0 No ❑ <br /> All samples received within holding time? Yes 0 No El <br /> (Exclude analyses that are considered field parameters <br /> such as pH,DO,Res Cl,Sulfite,Ferrous Iron,etc.) <br /> Temp Blank received in all shipping container(s)/cooler(s)? Yes 0 No Not Applicable <br /> Container/Temp Blank temperature: °C Melted Ice <br /> Containers requiring zero headspace have no headspace or Yes ❑ No No VOA vials submitted 0 <br /> bubble that is<6mm(1/4"). <br /> Water-pH acceptable upon receipt? Yes 0 No ❑ Not Applicable (� <br /> Standard Reporting Procedures: <br /> Lab measurement of analytes considered field parameters that require analysis within 15 minutes of sampling such as <br /> pH, Dissolved Oxygen and Residual Chlorine, are qualified as being analyzed outside of recommended holding time. <br /> Solid/soil samples are reported on a wet weight basis(as received) unless specifically indicated. If moisture corrected, <br /> data units are typically noted as—dry. For agricultural and mining soil parameters/characteristics, all samples are dried <br /> and ground prior to sample analysis. <br /> The reference date for Radon analysis is the sample collection date. The reference date for all other Radiochemical <br /> analyses is the analysis date. Radiochemical precision results represent a 2-sigma Total Measurement Uncertainty. <br /> Contact and Corrective Action Comments: <br /> Temperature Blank temperature of cooler 1 was 3.3°C, Cooler 2 was 12.8°C, Cooler 3 was 9.5°C, and Cooler 4 was <br /> 16.8°C. <br /> Cooler 2, 3, and 4 were all received with melted ice. 8/4/2022-KS <br /> Page 31 of 32 <br />