My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2022-08-01_HYDROLOGY - M1977300 (2)
DRMS
>
Day Forward
>
Hydrology
>
Minerals
>
M1977300
>
2022-08-01_HYDROLOGY - M1977300 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/2/2022 8:36:13 PM
Creation date
8/2/2022 8:08:39 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1977300
IBM Index Class Name
Hydrology
Doc Date
8/1/2022
Doc Name
Water Monitoring - Surface Water
From
Colorado Legacy Land
To
DRMS
Annual Report Year
2022
Report Quarter_Month
Jun
Email Name
AME
MAC
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ACZ Laboratories, Inc. • 11 UTIT, : • <br /> 2773 Downhill Drive Steamboat Springs,CO 80487 (800)334-5493 : • • <br /> Ensero Solutions ACZ Project ID: L73811 <br /> L73811-01 NG544683 Cyanide,WAD SM4500-CN I,E-Colonmetric w/ Q6 Sample was received above recommended temperature. <br /> distillation <br /> SM4500-CN I,E-Colodmetric w/ RA Relative Percent Difference(RPD)was not used for data <br /> distillation validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> WG545449 Fluoride SM450OF-C Q6 Sample was received above recommended temperature. <br /> WG545176 Nitrete/Nitnte as N M353.2-H2SO4 preserved 06 Sample was received above recommended temperature <br /> M353.2-H2SO4 preserved RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> W G544680 Phosphorus,total M365.1-Auto Ascorbic Acid Q6 Sample was received above recommended temperature. <br /> (digest) <br /> M365.1-Auto Ascorbic Acid RA Relative Percent Difference(RPD)was not used for data <br /> (digest) validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> WG544268 Residue,Filterable(TDS)@180C SM2540C N1 See Case Narrative. <br /> SM2540C Q6 Sample was received above recommended temperature. <br /> SM2540C RO The duplicate originally assigned to this sample was not <br /> used for precision assessment because residue density did <br /> not meet method limits. Another duplicate in the batch was <br /> used to assess precision. Method required duplicate <br /> frequency was not met. <br /> WG544219 Residue,Non-Filterable(TSS)@105C SM2540D Q6 Sample was received above recommended temperature. <br /> SM2540D RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> SM2540D Z3 Sample volume yielded a residue less than 2.5 mg <br /> WG545403 Sulfate D516-02/-0701- M2 Matrix spike recovery was low,the recovery of the <br /> TURBIDIMETRIC associated control sample(LCS or LFB)was acceptable <br /> 0516-02/-07/-11- Q6 Sample was received above recommended temperature. <br /> TURBIDIMETRIC <br /> L73811-02 VVG544683 Cyanide,WAD SM4500-CN I,E-Colonmetric w/ Q6 Sample was received above recommended temperature. <br /> distillation <br /> SM4500-CN I,E-Colorimetnc w/ RA Relative Percent Difference(RPD)was not used for data <br /> distillation validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG545449 Fluoride SM450OF-C Q6 Sample was received above recommended temperature. <br /> W G545176 Nitrate/Nitrite as N M353.2-H2SO4 preserved Q6 Sample was received above recommended temperature. <br /> M353 2-H2SO4 preserved RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1Ox MDL). <br /> W G544680 Phosphorus,total M365 1-Auto Ascorbic Acid Q6 Sample was received above recommended temperature. <br /> (digest) <br /> M365.1-Auto Ascorbic Acid RA Relative Percent Difference(RPD)was not used for data <br /> (digest) validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> WG544268 Residue,Filterable(TDS)@180C SM2540C N1 See Case Narrative <br /> SM2540C 06 Sample was received above recommended temperature. <br /> SM2540C RO The duplicate originally assigned to this sample was not <br /> used for precision assessment because residue density did <br /> not meet method limits. Another duplicate in the batch was <br /> used to assess precision Method required duplicate <br /> frequency was not met <br /> WG544317 Residue,Non-Filterable(TSS)@105C SM2540D Q6 Sample was received above recommended temperature. <br /> SM2540D Z3 Sample volume yielded a residue less than 2 5 mg <br /> WG545403 Sulfate D516-02/-07/-11- M2 Matrix spike recovery was low,the recovery of the <br /> TURBIDIMETRIC associated control sample(LCS or LFB)was acceptable. <br /> D516-02/-07/-11- Q6 Sample was received above recommended temperature <br /> TURBIDIMETRIC <br /> REPAD.15 06.05.01 <br /> L7381 1-220721 1 457 Page 14 of 24 <br />
The URL can be used to link to this page
Your browser does not support the video tag.