Laserfiche WebLink
ADZ Laboratories, Inc. • - • - • <br /> 2773 Downhill Dnve Steamboat Spnngs, CO 80487 (800)334-5493 WOTM. f s <br /> Ouray Silver Mines ACZ Project ID: L73468 <br /> L73468-01 NG543264 Chloride SM4500CI-E RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> WG543637 Cyanide,total M335 4-Colonmetric w/ RA Relative Percent Difference(RPD)was not used for data <br /> distillation validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL) <br /> WG543670 Fluoride SM450OF-C M2 Matrix spike recovery was low,the recovery of the <br /> associated control sample(LCS or LFB)was acceptable <br /> WG543610 Nitrate/Nitrite as N M353 2-H2SO4 preserved RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> W G543596 Phosphorus,total M365 1-Auto Ascorbic Acid RA Relative Percent Difference(RPD)was not used for data <br /> (digest) validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> WG543258 Residue,Filterable(TDS)@180C SM2540C RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG543353 Residue,Non-Filterable(TSS)@105C SM2540D RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> SM2540D Z3 Sample volume yielded a residue less than 2.5 mg <br /> L73468-02 NG543264 Chloride SM4500CI-E RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL) <br /> WG543637 Cyanide,total M335 4-Colorimetric w/ RA Relative Percent Difference(RPD)was not used for data <br /> distillation validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> WG543670 Fluoride SM450OF-C M2 Matrix spike recovery was low,the recovery of the <br /> associated control sample(LCS or LFB)was acceptable <br /> WG543610 Nitrate/Nitrite as N M353 2-H2SO4 preserved RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> W G543596 Phosphorus,total M365 1-Auto Ascorbic Acid RA Relative Percent Difference(RPD)was not used for data <br /> (digest) validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG543258 Residue,Filterable(TDS)@180C SM2540C RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> WG543353 Residue,Non-Filterable(TSS)@105C SM2540D RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> SM2540D Z3 Sample volume yielded a residue less than 2 5 mg <br /> L73468-03 NG543264 Chloride SM4500CI-E RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG543637 Cyanide,total M335 4-Colonmetric w/ RA Relative Percent Difference(RPD)was not used for data <br /> distillation validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG543670 Fluoride SM450OF-C M2 Matrix spike recovery was low,the recovery of the <br /> associated control sample(LCS or LFB)was acceptable <br /> WG543610 Nitrate/Nitrite as N M353 2-H2SO4 preserved RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> WG543596 Phosphorus,total M365 1-Auto Ascorbic Acid RA Relative Percent Difference(RPD)was not used for data <br /> (digest) validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> WG543258 Residue,Filterable(TDS)@180C SM2540C RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> WG543353 Residue,Non-Filterable(TSS)@105C SM2540D RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> SM2540D Z3 Sample volume yielded a residue less than 2 5 mg <br /> REPAD.15.06.05.01 <br /> L73468-2206151327 Page 19 of 24 <br />