Laserfiche WebLink
AC3Z Laboratories, Inc. i s <br /> 2773 Downhill Dnve Steamboat Spnngs, CO 80487 (800)334-5493 tl1 *s " <br /> ild <br /> Ouray Silver Mines ACZ Project ID: L73467 <br /> o s •� � a s <br /> L73467-01 NG543264 Chloride SM4500CI-E RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> WG546281 Cyanide,total M335 4-Colorimetric w/ HC Initial analysis within holding time Reanalysis was past <br /> distillation holding time,which was required due to a QC failure during <br /> the initial analysis. <br /> M335 4-Colorimetric w/ RA Relative Percent Difference(RPD)was not used for data <br /> distillation validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> W G543670 Fluoride SM450OF-C M2 Matrix spike recovery was low,the recovery of the <br /> associated control sample(LCS or LFB)was acceptable <br /> W G543610 Nitrate/Nitrite as N M353 2-H2SO4 preserved RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL) <br /> WG544046 Phosphorus,total M365 1-Auto Ascorbic Acid M3 The spike recovery value is unusable since the analyte <br /> (digest) concentration in the sample is disproportionate to the spike <br /> level The recovery of the associated control sample(LCS <br /> or LFB)was acceptable <br /> WG543258 Residue,Filterable(TDS)@180C SM2540C RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> WG543353 Residue,Non-Filterable(TSS)@105C SM2540D RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> SM2540D Z3 Sample volume yielded a residue less than 2 5 mg <br /> WG543192 Sulfate D516-02/-07/-11- M3 The spike recovery value is unusable since the analyte <br /> TURBIDIMETRIC concentration in the sample is disproportionate to the spike <br /> level The recovery of the associated control sample(LCS <br /> or LFB)was acceptable. <br /> L73467-02 NG543264 Chloride SM4500CI-E RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL) <br /> WG546281 Cyanide,total M335.4-Colonmetric w/ HC Initial analysis within holding time Reanalysis was past <br /> distillation holding time,which was required due to a QC failure during <br /> the initial analysis <br /> M335 4-Colorimetric w/ RA Relative Percent Difference(RPD)was not used for data <br /> distillation validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> W G543670 Fluoride SM450OF-C M2 Matrix spike recovery was low,the recovery of the <br /> associated control sample(LCS or LFB)was acceptable <br /> WG543610 Nitrate/Nitrite as N M353 2-H2SO4 preserved RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG544046 Phosphorus,total M365 1-Auto Ascorbic Acid M3 The spike recovery value is unusable since the analyte <br /> (digest) concentration in the sample is disproportionate to the spike <br /> level.The recovery of the associated control sample(LCS <br /> or LFB)was acceptable <br /> WG543258 Residue,Filterable(TDS)@180C SM2540C RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> WG543353 Residue,Non-Filterable(TSS)@105C SM2540D RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL) <br /> SM2540D Z3 Sample volume yielded a residue less than 2 5 mg <br /> WG543192 Sulfate D516-02/-07/-11- M3 The spike recovery value is unusable since the analyte <br /> TURBIDIMETRIC concentration in the sample is disproportionate to the spike <br /> level The recovery of the associated control sample(LCS <br /> or LFB)was acceptable <br /> REPAD.15.06.05.01 <br /> L73467-2207151358 Page 20 of 25 <br />