My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2022-06-03_HYDROLOGY - M1977300
DRMS
>
Day Forward
>
Hydrology
>
Minerals
>
M1977300
>
2022-06-03_HYDROLOGY - M1977300
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2024 7:28:41 PM
Creation date
6/3/2022 3:29:48 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1977300
IBM Index Class Name
Hydrology
Doc Date
6/3/2022
Doc Name
Water Monitoring - Surface Water
From
Colorado Legacy Land
To
DRMS
Email Name
AME
MAC
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ADZ Laboratories, Inc. • • • - • <br /> 2773 Downhill Drive Steamboat Springs, CO 80487 (800)334-5493 - • • <br /> Ensero Solutions ACZ Project ID: L72339 <br /> METHODACZ ID WORKNUM PARAMETER QUAL DESCRIPTION <br /> L72339.01 NG540767 Antimony,total recoverable M200.8 ICP-MS LA Recovery for target analyte in the control sample(LCS or <br /> LFB)exceeded the acceptance criteria. Target analyte was <br /> not detected in the sample[<MDL]. <br /> WG539842 Cyanide,WAD SM4500-CN I,E-Colodmetric w/ Q6 Sample was received above recommended temperature <br /> distillation <br /> SM4500-CN I,E-Colorimetric w/ RA Relative Percent Difference(RPD)was not used for data <br /> distillation validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG540645 Fluoride SM450OF-C Q6 Sample was received above recommended temperature. <br /> WG540746 Molybdenum,dissolved M200 7 ICP VC CCV recovery was above the acceptance limits Target <br /> analyte was not detected in the sample[<MDL] <br /> WG540857 Nitrate/Nitrite as N M353 2-H2SO4 preserved Q6 Sample was received above recommended temperature. <br /> M353 2-H2SO4 preserved RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<lox MDL) <br /> WG539918 Phosphorus,total M365.1-Auto Ascorbic Acid M2 Matrix spike recovery was low,the recovery of the <br /> (digest) associated control sample(LCS or LFB)was acceptable <br /> M365.1-Auto Ascorbic Acid Q6 Sample was received above recommended temperature. <br /> (digest) <br /> M365.1-Auto Ascorbic Acid RA Relative Percent Difference(RPD)was not used for data <br /> (digest) validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL) <br /> WG539704 Residue,Filterable(TDS)@180C SM2540C Q6 Sample was received above recommended temperature. <br /> WG539797 Residue,Non-Filterable(TSS)@105C SM2540D Q6 Sample was received above recommended temperature. <br /> SM2540D RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> SM2540D Z3 Sample volume yielded a residue less than 2.5 mg <br /> WG540541 Sulfate D516-02/-07/-11- 06 Sample was received above recommended temperature. <br /> TURBIDIMETRIC <br /> L72339-02 NG540767 Antimony,total recoverable M200.8 ICP-MS LA Recovery for target analyte in the control sample(LCS or <br /> LFB)exceeded the acceptance crtena. Target analyte was <br /> not detected in the sample[<MDL] <br /> WG539842 Cyanide,WAD SM4500-CN I,E-Colorimetric w/ Q6 Sample was received above recommended temperature <br /> distillation <br /> SM4500-CN I,E-Colonmetnc w/ RA Relative Percent Difference(RPD)was not used for data <br /> distillation validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> WG540645 Fluoride SM450OF-C Q6 Sample was received above recommended temperature. <br /> WG540746 Molybdenum,dissolved M200 7 ICP VC CCV recovery was above the acceptance limits Target <br /> analyte was not detected in the sample[<MDL] <br /> WG540857 Nitrate/Nitrite as N M353.2-H2SO4 preserved Q6 Sample was received above recommended temperature <br /> M353 2-H2SO4 preserved RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG539918 Phosphorus,total M365 1-Auto Ascorbic Acid M2 Matrix spike recovery was low,the recovery of the <br /> (digest) associated control sample(LCS or LFB)was acceptable. <br /> M365.1-Auto Ascorbic Acid Q6 Sample was received above recommended temperature <br /> (digest) <br /> M365.1-Auto Ascorbic Acid RA Relative Percent Difference(RPD)was not used for data <br /> (digest) validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> WG539704 Residue,Filterable(TDS)@180C SM2540C Q6 Sample was received above recommended temperature <br /> WG539797 Residue,Non-Filterable(TSS)@105C SM2540D Q6 Sample was received above recommended temperature. <br /> SM2540D RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> SM2540D Z3 Sample volume yielded a residue less than 2 5 mg <br /> WG540541 Sulfate D516-02/-07/-1 l- Q6 Sample was received above recommended temperature. <br /> TURBIDIMETRIC <br /> REPAD.15.06.05.01 <br /> L72339-2205261013 Page 12 of 22 <br />
The URL can be used to link to this page
Your browser does not support the video tag.