ACZ Laboratories, Inc. • • • - • <br /> 2773 Downhill Drive Steamboat Springs, CO 80487 (800)334-5493 - • • <br /> Ouray Silver Mines ACZ Project ID: L71783 <br /> METHOD'ACZ ID WORKNUM PARAMETER QUAL DESCRIPTION <br /> L71783-01 NG538059 Calcium,dissolved M200.7 ICP M3 The spike recovery value is unusable since the analyte <br /> concentration in the sample is disproportionate to the spike <br /> level.The recovery of the associated control sample(LCS <br /> or LFB)was acceptable. <br /> WG537794 Cyanide,total M335.4-Colorimetric w/ M1 Matrix spike recovery was high,the recovery of the <br /> distillation associated control sample(LCS or LFB)was acceptable. <br /> WG538429 Fluoride SM450OF-C Mt Matrix spike recovery was high,the recovery of the <br /> associated control sample(LCS or LFB)was acceptable. <br /> WG537900 Phosphorus,total M365.1-Auto Ascorbic Acid RA Relative Percent Difference(RPD)was not used for data <br /> (digest) validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1Ox MDL). <br /> WG537803 Residue,Non-Filterable(TSS)@105C SM2540D RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> SM2540D Z3 Sample volume yielded a residue less than 2.5 mg <br /> W G538250 Sulfate D516-02/-07/-11- M3 The spike recovery value is unusable since the analyte <br /> TURBIDIMETRIC concentration in the sample is disproportionate to the spike <br /> level.The recovery of the associated control sample(LCS <br /> or LFB)was acceptable. <br /> L71783-02 ✓•/G537794 Cyanide,total M335.4-Colorimetric w/ M1 Matrix spike recovery was high,the recovery of the <br /> distillation associated control sample(LCS or LFB)was acceptable. <br /> WG538429 Fluoride SM450OF-C M1 Matrix spike recovery was high,the recovery of the <br /> associated control sample(LCS or LFB)was acceptable. <br /> WG537900 Phosphorus,total M365.1-Auto Ascorbic Acid RA Relative Percent Difference(RPD)was not used for data <br /> (digest) validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> WG537803 Residue,Non-Filterable(TSS)@105C SM2540D RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> SM2540D Z3 Sample volume yielded a residue less than 2.5 mg <br /> W G538250 Sulfate D516-02/-07/-1 l- M3 The spike recovery value is unusable since the analyte <br /> TURBIDIMETRIC concentration in the sample is disproportionate to the spike <br /> level.The recovery of the associated control sample(LCS <br /> or LFB)was acceptable. <br /> REPAD.15.06.05.01 <br /> L71783-2203231609 Page 15 of 19 <br />