My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2022-02-07_HYDROLOGY - M1977300 (2)
DRMS
>
Day Forward
>
Hydrology
>
Minerals
>
M1977300
>
2022-02-07_HYDROLOGY - M1977300 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2024 6:33:11 PM
Creation date
2/8/2022 9:45:30 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1977300
IBM Index Class Name
Hydrology
Doc Date
2/7/2022
Doc Name
Water Monitoring - Surface Water
From
Colorado Legacy Land
To
WQCD
Annual Report Year
2021
Report Quarter_Month
Dec
Email Name
AME
MAC
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ADZ Laboratories, Inc. <br /> 2773 Downhill Dnve Steamboat Spnngs,CO 80487 (800)334-5493 <br /> Report Header Explanations <br /> Batch A distinct set of samples analyzed at a specific time <br /> Found Value of the QC Type of interest <br /> Limit Upper limit for RPD,in%. <br /> Lower Lower Recovery Limit,in% (except for LCSS,mg/Kg) <br /> MDL Method Detection Limit Same as Minimum Reporting Limit unless omitted or equal to the PQL(see comment#5) <br /> Allows for instrument and annual fluctuations. <br /> PCN/SCN A number assigned to reagents/standards to trace to the manufacturers certificate of analysis <br /> PQL Practical Quantitation Limit. Synonymous with the EPA term"minimum level". <br /> QC True Value of the Control Sample or the amount added to the Spike <br /> Rec Recovered amount of the true value or spike added,in%(except for LCSS,mg/Kg) <br /> RPD Relative Percent Difference,calculation used for Duplicate QC Types <br /> Upper Upper Recovery Limit,in% (except for LCSS,mg/Kg) <br /> Sample Value of the Sample of interest <br /> OC Sample Types <br /> AS Analytical Spike(Post Digestion) LCSWD Laboratory Control Sample-Water Duplicate <br /> ASD Analytical Spike(Post Digestion)Duplicate LFB Laboratory Fortified Blank <br /> CCB Continuing Calibration Blank LFM Laboratory Fortified Matra <br /> CCV Continuing Calibration Verification standard LFMD Laboratory Fortified Matra Duplicate <br /> DUP Sample Duplicate LRB Laboratory Reagent Blank <br /> ICB Initial Calibration Blank MS Matrix Spike <br /> ICV Initial Calibration Verification standard MSD Matrix Spike Duplicate <br /> ICSAB Inter-element Correction Standard-AplusBsolutions PBS Prep Blank-Soil <br /> LCSS Laboratory Control Sample-Soil PB W Prep Blank-Water <br /> LCSSD Laboratory Control Sample-Soil Duplicate PQV Practical Quantitation Venficetion standard <br /> LCSW Laboratory Control Sample-Water SDL Serial Dilution <br /> QC Sample Type Explanations <br /> Blanks Verifies that there is no or minimal contamination in the prep method or calibration procedure. <br /> Control Samples Verifies the accuracy of the method,including the prep procedure. <br /> Duplicates Verifies the precision of the instrument and/or method <br /> Spikes/Fortified Matra Determines sample matrix interferences,if any. <br /> Standard Verifies the validity of the calibration. <br /> ACZ Qualifiers • . <br /> B Analyte concentration detected at a value between MDL and PQL The associated value is an estimated quantity. <br /> H Analysis exceeded method hold time. pH is a field test with an immediate hold time. <br /> L Target analyte response was below the laboratory defined negative threshold <br /> U The material was analyzed for,but was not detected above the level of the associated value <br /> The associated value is either the sample quantitaton limit or the sample detection limit <br /> Method References <br /> (1) EPA 600/4-83-020. Methods for Chemical Analysis of Water and Wastes,March 1983 <br /> (2) EPA 600/R-93-100 Methods for the Determination of Inorganic Substances in Environmental Samples,August 1993. <br /> (3) EPA 600/R-94-111 Methods for the Determination of Metals in Environmental Samples-Supplement I,May 1994. <br /> (4) EPA SW-846. Test Methods for Evaluating Solid Waste. <br /> (5) Standard Methods for the Examination of Water and Wastewater. <br /> Comments <br /> (1) QC results calculated from raw data. Results may vary slightly it the rounded values are used in the calculations <br /> (2) Soil,Sludge,and Plant matrices for Inorganic analyses are reported on a dry weight basis <br /> (3) Animal matrices for Inorganic analyses are reported on an"as received"basis. <br /> (4) An asterisk in the"XQ"column indicates there is an extended qualifier and/or certification qualifier <br /> associated with the result. <br /> (5) If the MDL equals the PQL or the MDL column is omitted,the PQL is the reporting limit <br /> For a complete list of ACZ's Extended Qualifiers,please click: <br /> https:Hacz.coin/wp-content/u ploads/2019/04/Ex t-Oua I-Li st.pdf <br /> REP001 03 15.02 <br /> L70424-2201310853 Page 4 of 23 <br />
The URL can be used to link to this page
Your browser does not support the video tag.