2022-02-07_HYDROLOGY - M1977300 (2)
DRMS
>
Day Forward
>
Hydrology
>
Minerals
>
M1977300
>
2022-02-07_HYDROLOGY - M1977300 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2024 6:33:11 PM
Creation date
2/8/2022 9:45:30 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1977300
IBM Index Class Name
Hydrology
Doc Date
2/7/2022
Doc Name
Water Monitoring - Surface Water
From
Colorado Legacy Land
To
WQCD
Annual Report Year
2021
Report Quarter_Month
Dec
Email Name
AME
MAC
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ADZ Laboratories, Inc. • • - • - • <br /> 2773 Downhill Drive Steamboat Sprigs,CO 80487 (800)334-5493 - • • <br /> Ensero Solutions ACZ Project ID: L70424 <br /> METHODACZ ID WORKNUM PARAMETER QUAL DESCRIPTION <br /> L70424-01 NG534480 Antimony,total recoverable M200 8 ICP-MS M3 The spike recovery value is unusable since the analyte <br /> concentration in the sample is disproportionate to the spike <br /> level.The recovery of the associated control sample(LCS <br /> or LFB)was acceptable. <br /> WG533955 Cyanide,WAD SM4500-CN I,E-Colorimetric w/ RA Relative Percent Difference(RPD)was not used for data <br /> distillation validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> WG534197 NRrate/NRnte as N M353.2-H2SO4 preserved RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> WG534316 Phosphorus,total M365 1-Auto Ascorbic Acid RA Relative Percent Difference(RPD)was not used for data <br /> (digest) validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> WG533540 Residue,Non-FiRerable(TSS)@105C SM2540D RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<lox MDL). <br /> SM2540D Z3 Sample volume yielded a residue less than 2 5 mg <br /> WG534737 Uranium,total M200 8 ICP-MS M3 The spike recovery value is unusable since the analyte <br /> concentration in the sample is disproportionate to the spike <br /> level The recovery of the associated control sample(LCS <br /> or LFB)was acceptable <br /> L70424-02 NG534480 Antimony,total recoverable M200.8 ICP-MS M3 The spike recovery value is unusable since the analyte <br /> concentration in the sample is disproportionate to the spike <br /> level.The recovery of the associated control sample(LCS <br /> or LFB)was acceptable. <br /> WG533955 Cyanide,WAD SM4500-CN I,E-Colorimetric w/ RA Relative Percent Difference(RPD)was not used for data <br /> distillation validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> WG534197 Nitrate/Nitrite as N M353.2-H2SO4 preserved RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> WG534316 Phosphorus,total M365.1-Auto Ascorbic Acid RA Relative Percent Difference(RPD)was not used for data <br /> (digest) validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL) <br /> WG533540 Residue,Non-FiRerable(TSS)@105C SM2540D RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> SM2540D Z3 Sample volume yielded a residue less than 2 5 mg <br /> WG534737 Uranium,total M200 8 ICP-MS M3 The spike recovery value is unusable since the analyte <br /> concentration in the sample is disproportionate to the spike <br /> level.The recovery of the associated control sample(LCS <br /> or LFB)was acceptable. <br /> REPAD.15.06.05.01 <br /> L70424-2201310853 Page 13 of 23 <br />