Laserfiche WebLink
ACZ Laboratories, Inc. <br /> 2773 Downhill Drive Steamboat Spnngs,CO 80487 (800)334-5493 <br /> Report Header Explanations <br /> Batch A district set of samples analyzed at a specific time <br /> Found Value of the QC Type of interest <br /> Limit Upper limit for RPD,in%. <br /> Lower Lower Recovery Limit,in% (except for LCSS,mg/Kg) <br /> MDL Method Detection Limit Same as Minimum Reporting Limit unless omitted or equal to the PQL(see comment#5). <br /> Allows for instrument and annual fluctuations. <br /> PCN/SCN A number assigned to reagents/standards to trace to the manufacturers certificate of analysis <br /> PQL Practical Quantitation Limit Synonymous with the EPA term"minimum level" <br /> QC True Value of the Control Sample or the amount added to the Spike <br /> Rec Recovered amount of the true value or spike added,in%(except for LCSS,mg/Kg) <br /> RPD Relative Percent Difference,calculation used for Duplicate QC Types <br /> Upper Upper Recovery Limit,in% (except for LCSS,mg/Kg) <br /> Sample Value of the Sample of interest <br /> IQC Sample Types <br /> AS Analytical Spike(Post Digestion) LCSWD Laboratory Control Sample-Water Duplicate <br /> ASD Analytical Spike(Post Digestion)Duplicate LFB Laboratory Fortified Blank <br /> CCB Continuing Calibration Blank LFM Laboratory Fortified Matrix <br /> CCV Continuing Calibration Venfication standard LFMD Laboratory Fortified Matrix Duplicate <br /> DUP Sample Duplicate LRB Laboratory Reagent Blank <br /> ICB Initial Calibration Blank MS Matrix Spike <br /> ICV Initial Calibration Verification standard MSD Matrix Spike Duplicate <br /> ICSAB Inter-element Correction Standard-A plus B solutions PBS Prep Blank-Soil <br /> LCSS Laboratory Control Sample-Soil PBW Prep Blank-Water <br /> LCSSD Laboratory Control Sample-Soil Duplicate PQV Practical Quantitatron Verification standard <br /> LCSW Laboratory Control Sample-Water SDL Serial Dilution <br /> QC Sample Type Explanations <br /> Blanks Verifies that there is no or minimal contamination in the prep method or calibration procedure <br /> Control Samples Verifies the accuracy of the method,including the prep procedure <br /> Duplicates Verifies the precision of the instrument and/or method <br /> Spikes/Fortified Matrix Determines sample matrix interferences,if any <br /> Standard Verifies the validity of the calibration. <br /> • . <br /> B Analyte concentration detected at a value between MDL and PQL The assoaated value is an estimated quantity. <br /> H Analysis exceeded method hold time pH is afield test with an immediate hold time. <br /> L Target anayte response was below the laboratory defined negative threshold. <br /> U The matenal was analyzed for,but was not detected above the level of the associated value <br /> The associated value is either the sample quantitatron limit or the sample detection limit <br /> Method References <br /> (1) EPA 600/4-83-020 Methods for Chemical Analysis of Water and Wastes,March 1983. <br /> (2) EPA 600/R-93-100 Methods for the Determination of Inorganic Substances in Environmental Samples,August 1993. <br /> (3) EPA 600/R-94-111. Methods for the Determination of Metals in Environmental Samples-Supplement I,May 1994, <br /> (4) EPA SW-846. Test Methods for Evaluating Solid Waste <br /> (5) Standard Methods for the Examination of Water and Wastewater <br /> (1) QC results calculated from raw data. Results may vary slightly 6 the rounded values are used in the calculations. <br /> (2) Soil,Sludge,and Plant matrices for Inorganic analyses are reported on a dry weight basis <br /> (3) Animal matrices for Inorganic analyses are reported on an"as received"basis. <br /> (4) An asterisk in the"XQ"column indicates there is an extended qualifier and/or certification qualifier <br /> associated with the result <br /> (5) If the MDL equals the PQL or the MDL column is omitted,the PQL is the reporting limit. <br /> For a complete list of ACZ's Extended Qualifiers,please click <br /> https://acz.com/wl2-content/upload42019/04/Ext-Oual-Li st.pdf <br /> REP001 03 15 02 <br /> L70091-2201 271 1 35 Page 5 of 23 <br />