My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2021-12-07_REVISION - M2012032 (11)
DRMS
>
Day Forward
>
Revision
>
Minerals
>
M2012032
>
2021-12-07_REVISION - M2012032 (11)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/7/2021 11:13:38 AM
Creation date
12/7/2021 11:07:40 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M2012032
IBM Index Class Name
Revision
Doc Date
12/7/2021
Doc Name Note
Appendix 7: SPLP Results for Waste Rock
Doc Name
Proposed Revision Materials
From
Ouray Silver Mines, Inc
To
DRMS
Type & Sequence
AM2
Email Name
LJW
THM
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ADZ Laboratories, Inc. • • - • - • <br /> 2773 Downhill Drive Steamboat Springs, CO 80487 (800)334-5493 - • • <br /> Ouray Silver Mines ACZ Project ID: L68141 <br /> METHODACZ ID WORKNUM PARAMETER QUAL DESCRIPTION <br /> L68141-01 NG527063 Aluminum(1312) M6010D ICP RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG527407 Beryllium(1312) M6020B ICP-MS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG527173 Bicarbonate as CaCO3 SM2320B-Titration Q6 Sample was received above recommended temperature. <br /> WG527063 Boron(1312) M6010D ICP RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG526898 Bromide(1312-DI) M300.0-Ion Chromatography HD Analysis is outside the intended scope of the method,which <br /> does not provide hold time information for soil extracts. No <br /> hold time is observed for collection to extraction. The <br /> referenced method hold time is observed for extraction-to- <br /> analysis. <br /> M300.0-Ion Chromatography M2 Matrix spike recovery was low,the recovery of the <br /> associated control sample(LCS or LFB)was acceptable. <br /> M300.0-Ion Chromatography RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG527407 Cadmium(1312) M6020B ICP-MS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG527704 Carbon,total organic(TOC)(1312-DI) SM5310B HD Analysis is outside the intended scope of the method,which <br /> does not provide hold time information for soil extracts. No <br /> hold time is observed for collection to extraction. The <br /> referenced method hold time is observed for extraction-to- <br /> analysis. <br /> SM5310B Q6 Sample was received above recommended temperature. <br /> SM5310B RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG527173 Carbonate as CaCO3 SM2320B-Titration Q6 Sample was received above recommended temperature. <br /> WG526898 Chloride(1312-DI) M300.0-Ion Chromatography HD Analysis is outside the intended scope of the method,which <br /> does not provide hold time information for soil extracts. No <br /> hold time is observed for collection to extraction. The <br /> referenced method hold time is observed for extraction-to- <br /> analysis. <br /> M300.0-Ion Chromatography RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> WG527407 Chromium(1312) M6020B ICP-MS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> Cobalt(1312) M6020B ICP-MS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG527173 Conductivity @25C(1312-DI) SM2510B Q6 Sample was received above recommended temperature. <br /> WG527407 Copper(1312) M6020B ICP-MS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> WG527502 Fluoride(1312 DI) SM450OF-C RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> WG527173 Hydroxide as CaCO3 SM2320B-Titration Q6 Sample was received above recommended temperature. <br /> WG527063 Iron(1312) M6010D ICP RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> Lithium(1312) M6010D ICP RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> Magnesium(1312) M6010D ICP RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> WG527013 Mercury(1312) M7470A CVAA Q6 Sample was received above recommended temperature. <br /> R E PAD.15.06.05.01 <br /> L681 41-21 09301 047 Page 17 of 23 <br />
The URL can be used to link to this page
Your browser does not support the video tag.