Laserfiche WebLink
ACZ Laboratories, Inc. • - • - • <br /> 2773 Downhill Dnve Steamboat Spnngs, CO 80487 (800)334-5493 - • • <br /> Ensero Solutions ACZ Project ID: L68577 <br /> METHODACZ ID WORKNUM PARAMETE QUAL DESCRIPTION <br /> L68577-01 NG527970 Cyanide,WAD SM4500-CN I,E-Colonmetric w/ RA Relative Percent Difference(RPD)was not used for data <br /> distillation validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL) <br /> WG528529 Nitrate/Nitnte as N M353.2-H2SO4 preserved RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> WG528205 Phosphorus,total M365 1-Auto Ascorbic Acid RA Relative Percent Difference(RPD)was not used for data <br /> (digest) validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL) <br /> WG527762 Residue,Non-Filterable(TSS)@105C SM2540D RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1Ox MDL) <br /> SM2540D Z3 Sample volume yielded a residue less than 2.5 mg <br /> WG529064 Silver,dissolved M200.8 ICP-MS M2 Matrix spike recovery was low,the recovery of the <br /> associated control sample(LCS or LFB)was acceptable. <br /> M200 8 ICP-MS ZA Poor recovery for Silver quality control is accepted due to <br /> low Silver solubility in samples,digestates,or extracts that <br /> do not contain sufficient Hydrochloric acid <br /> WG528257 Sulfate D516-02/-07/-11- M3 The spike recovery value is unusable since the analyte <br /> TURBIDIMETRIC concentration in the sample is disproportionate to the spike <br /> level.The recovery of the associated control sample(LCS <br /> or LFB)was acceptable. <br /> D516-02/-07/-11- RA Relative Percent Difference(RPD)was not used for data <br /> TURBIDIMETRIC validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL) <br /> WG528509 Uranium,total M200.8 ICP-MS M1 Matrix spike recovery was high,the recovery of the <br /> associated control sample(LCS or LFB)was acceptable <br /> WG528409 Zinc,dissolved M200 7 ICP MA Recovery for either the spike or spike duplicate was outside <br /> of the acceptance limits;the RPD was within the <br /> acceptance limits <br /> REPAD 15.06.05.01 <br /> L68577-21 1 1 1 61 058 Page 12 of 21 <br />