My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2021-09-27_REVISION - M1990057
DRMS
>
Day Forward
>
Revision
>
Minerals
>
M1990057
>
2021-09-27_REVISION - M1990057
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/12/2025 2:02:19 AM
Creation date
9/27/2021 4:35:44 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1990057
IBM Index Class Name
REVISION
Doc Date
9/27/2021
Doc Name
Adequacy Review Response
From
The Union Milling Contractors
To
DRMS
Type & Sequence
CN1
Email Name
DMC
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
133
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mr. Dustin Czapla 10 <br /> CDRMS <br /> September 24, 2021 <br /> Deposits are generally poorly sorted to unsorted. Because of the lithologic heterogeneity, <br /> stratigraphic correlation with the existing regional and areas of interest, lithologic correlation is <br /> not feasible <br /> Local groundwater flow is illustrated on Figure 21-1 (See attached Appendix 7-1 Groundwater <br /> Flow Network Well Logs). Groundwater information and water quality data is presented in detail <br /> in section 21.0 Rule 6.4.21 Section 21.8 and Section 21.9. See response below regarding <br /> strata formation, characterization, and earthquakes. <br /> 16. Rule 6.4.21 EXHIBIT U — Environmental Protection Plan - Surface Water Control <br /> and Containment Facilities Information <br /> Pursuant to Rule 6.4.21 (10)(a) please provide design specifications certified by a <br /> licensed professional engineer for all Environmental Protection Facilities (mill and <br /> TSF) intended to: <br /> (i) hold, convey, contain, or transport designated chemicals used in the extractive <br /> metallurgical process. <br /> Response <br /> The TSF, as currently permitted, is under construction. When completed it will be signed-off by <br /> Simbeck Construction, and as-built drawings provided by the contractor. In addition, we will <br /> provide design specifications for all overpack containers that will hold reagents prior to use once <br /> purchased. <br /> CJK commits to make approval of the above item as condition of permit approval. <br /> 17. Rule 6.4.21 EXHIBIT U — Environmental Protection Plan — Water Quality <br /> Monitoring Plan <br /> Your application provides a water quality monitoring plan pursuant to Rule 6.4.21 <br /> (12) on page 21-24 of the application. The application describes two existing <br /> monitoring wells, MW-2 and MW-3. Figure 3-3 of Exhibit E shows MW-3 up-gradient <br /> of the existing 110 permit affected area and MW-2 as the point of compliance well <br /> at the southwest corner of the property. In order to monitor water quality potentially <br /> affected by the mill area the Division would like to see another down-gradient <br /> monitoring well installed southwest of the mill building and northwest of the TSF, <br /> near the west permit boundary at approximate coordinates 39.230008°, - <br /> 106.333338°. Please commit to installation of this additional monitoring well and <br /> incorporation into the proposed water quality monitoring plan. <br /> Response <br /> As suggested, CJK will install an additional monitoring wel12 (See Figure 21-2) and sample per <br /> CJK's approved groundwater monitoring program. <br /> Section 7.0 Rule 6.4.7 Exhibit G Water Information, Section 21.7.4-Monitoring Systems, Section <br /> 21.9 - Groundwater Quality Data, Section 21.12 - Mill Water Quality Monitoring Plan, Appendix <br /> 21-3 thru Appendix 21-9 Standard Operating Procedures (SOPs) in permit. <br /> 18. Rule 6.4.21 EXHIBIT U — Environmental Protection Plan -Climate <br /> Pursuant to Rule 6.4.21 (13)(a) provide adequate climatic data representative of the <br /> site to perform an acceptable "water balance" for all liquid containment systems <br /> Approximate coordinates 39.230008°,-106.333338°. <br />
The URL can be used to link to this page
Your browser does not support the video tag.