ADZ Laboratories, Inc. • - - • - • <br /> 2773 Downhill Drive Steamboat Springs, CO 80467 (800)334-5493 R - • • <br /> Ensero Solutions ACZ Project ID: L66559 <br /> METHOD:ACZ ID WORKNUM PARAMETER QUAL DESCRIPTION <br /> L66559-01 JVG521742 Cyanide,WAD SM4500-CN I,E-Colorimetric w/ M2 Matrix spike recovery was low,the recovery of the <br /> distillation associated control sample(LCS or LFB)was acceptable. <br /> SM4500-CN I,E-Colorimetric w/ Q6 Sample was received above recommended temperature. <br /> distillation <br /> SM4500-CN I,E-Colorimetric w/ RA Relative Percent Difference(RPD)was not used for data <br /> distillation validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG522332 Fluoride SM450OF-C M2 Matrix spike recovery was low,the recovery of the <br /> associated control sample(LCS or LFB)was acceptable. <br /> SM450OF-C Q6 Sample was received above recommended temperature. <br /> WG522501 Nitrate/Nitrite as N M353.2-H2SO4 preserved Q6 Sample was received above recommended temperature. <br /> M353.2-H2SO4 preserved RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG522201 Phosphorus,total M365.1-Auto Ascorbic Acid Q6 Sample was received above recommended temperature. <br /> (digest) <br /> M365.1-Auto Ascorbic Acid RA Relative Percent Difference(RPD)was not used for data <br /> (digest) validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> WG521521 Residue,Filterable(TDS)@180C SM2540C Q6 Sample was received above recommended temperature. <br /> SM2540C RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> WG521721 Residue,Non-Filterable(TSS)@105C SM2540D HC Initial analysis within holding time.Reanalysis was past <br /> holding time,which was required due to a QC failure during <br /> the initial analysis. <br /> SM2540D Q6 Sample was received above recommended temperature. <br /> SM2540D RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> SM2540D Z3 Sample volume yielded a residue less than 2.5 mg <br /> WG522738 Sulfate D516-02/-07/-11- M3 The spike recovery value is unusable since the analyte <br /> TURBIDIMETRIC concentration in the sample is disproportionate to the spike <br /> level.The recovery of the associated control sample(LCS <br /> or LFB)was acceptable. <br /> D516-02/-07/-11- Q6 Sample was received above recommended temperature. <br /> TURBIDIMETRIC <br /> WG522274 Total Hot Plate Digestion M200.2 ICP DJ Sample dilution required due to insufficient sample. <br /> WG522305 M200.2 ICP-MS DJ Sample dilution required due to insufficient sample. <br /> REPAD.15.06.05.01 <br /> L66559-2108181147 Page 12 of 23 <br />