Laserfiche WebLink
85'MIN <br /> 70' 315' <br /> SLURRY WALL <br /> CENTERLINE EXISTING GROUND <br /> NWL=4595.9 I•f-25'--•I 10'1­ 3' <br /> .. _ BACKFILL MIXING AREA (MIN) <br /> STOCKPILED SUPPLEMENTAL FINES <br /> 3 �HVI SLURRY WALL <br /> FINAL SLOPE WORKING PLATFORM MAINTAIN SLURRY LEVEL AS <br /> CLOSE TO GROUND SURFACE <br /> CONFINEMENTS <br /> AS POSSIBLE CONFINEMENT BERM <br /> AND/OR SILT FENCE AND/OR SILT FENCE <br /> SLURRY WALL WHERE NECESSARY WHERE NECESSARY <br /> (SOIL-BENTONITE) �TT/7TT �7"/-/7T'T/7TT/7TT/7 <br /> PLATFORM FILL//////////////// l,'IAI PLATFORMFILL <br /> T. <br /> `;. <br /> APPROXIMATESLURRY WALL.. '`. <br /> TOP OF BEDROCK .:..:...:.:....::. ... ,..: (CEMENT-SOIL-BENTONITE)_. <br /> — � � _ � � , WEATHEREDBEDRO <br /> .:...:.:.. <br /> FINAL SLOPE DETAIL T /��T�/,/ <br /> SUITABLE <br /> 0 30' 60' //// <br /> SCALE IN FEET TRENCH BOTTOM <br /> KEYED 4'MIN.INTO <br /> SUITABLE BEDROCK, <br /> TYPICAL SLURRY WALL DETAIL <br /> NOT TO SCALE <br /> 4.5' 19, 4.5' <br /> 10' 2.5' 10' <br /> r6'STEEL"T"POST IN CENTER OF SLURRY WALL SLOPE 3:1 OR SLOPE 3:1 OR <br /> TO IDENTIFY CENTERLINE OF AS-CONSTRUCTED FEATHER AT FLATTER FEATHER AT FLATTER <br /> SPREAD EXCESS TRENCHED AND ALIGNMENT.MAXIMUM SPACING 1DO'ON CENTER AND SLOPES AS SLOPES AS <br /> BACK FILL MATERIAL TO THE PR ALL ANGLE POINTS OR POINTS OF TANGENCY NECESSARY 1'CLASS 5 ROADBASE NECESSARY <br /> SIDE OF THE SLURRY WALL. <br /> O O o 0 0 Oo 0 0 0 o p o p0 0 0 o p p p o 0 <br /> 10' 3' 3' 3' o 0 0o C o o 0 0 0 0 o O o 0 0 0 0 0 o 0 <br /> 3 (NOMINAL) FILTER CLOTH OVERLAIN 16"CRUSHED ROCK <br /> —11 1' MIN.OR GREATER <br /> - TO TOP OF EXISTING BY GEOGRID FABRIC TO MEET REQUIRED <br /> `EXISTING SLURRY WALL X WORKING PLATFORM (AASHTO CLASS 2 TOP OF SLURRY WALL ROAD GRADE <br /> WORKING PLATFORM NONWOVEN SEPARATION 0 TOP OF EXISTING <br /> NOTES: FABRIC 8 TENSAR 1600 WORKING PLATFORM <br /> LCLAYEY SOIL OR 1. CAP SHALL BE CONSTRUCTED,WITH T POST INSTALLED AS REQUIRED OR EQUIVALENT)OR 0.5" <br /> S-B BACKFILL WITHIN 200'OF THE ACTIVE BACKFILL MIXING AREA. STEEL PLATE <br /> SOIL BENTONITE <br /> BACKFILL 2. CAP MAY REQUIRE LOCAL FIELD ADJUSTMENT TO MEET FINAL GRADING <br /> 3.0'MIN PLAN REQUIREMENTS,AS NECESSARY,TO MEET PROJECT INTENT. <br /> SOIL BENTONITE <br /> 3. AFTER PRIMARY CONSOLIDATION OF THE SLURRY WALL,OWNER SHALL BACKFILL <br /> PROVIDE FINAL GRADING OF CAP MATERIAL AND EXCESS MATERIAL 3.0'MIN <br /> STOCKPILES PER RECLAMATION PLAN. <br /> SLURRY WALL TRENCH CAP DETAIL PERMANENT ROAD CROSSING DETAIL <br /> NOT TO SCALE NOT TO SCALE <br /> 3 NOTES: <br /> v/z <br /> 1. PERMANENT ROAD CROSSING TO BE LOCATED AT OWNER'S DIRECTION. <br /> 3 10, <br /> Supplemental Dry Bentonite Spacing MIN. TIE-IN TAB <br /> Start End Cast Out Fines Application Rate Between Bags <br /> Station Station % (CY/LF) (lbs/LF) (30001b bag) <br /> Feet DIRECTION OF EXCAVATION <br /> 0+00 8+00 10 1 288.12 13 AND SOIL BENTONITE <br /> BACKFILL PLACEMENT <br /> 8+10 14+90 30 2.75 295.3 10 f <br /> 15+00 37+50 45 5.2 374.2 8 <br /> 37+60 47+90 45 4 266.7 11 <br /> 48+00 63+00 30 3.3 369.2 8 <br /> 63+10 72+00 30 2.5 243.44 12 <br /> 72+00 78+90 10 1 288.12 13 I a z° <br /> _ TO' <br /> I N O <br /> 1. TABLE BASED ON SUPPLEMENTAL FINES WITH AN AVERAGE OF 80%PASSING THE#200 SIEVE. O O <br /> q CUTOFF WALL ALIGNMENT z <br /> v M <br /> O <br /> 2. RATES SHOWN ARE FOR A MINIMUM OF 30%PASSING#200 SIEVE FOR S-B BACKFILL AND MAY REQUIRE csi Z m <br /> ADJUSTMENT. NOTES: I 3 z x <br /> 3 3. BAG SPACING BASED ON A DRY BENTONITE APPLICATION RATE OF 1%AND MAY BE ADJUSTED BASED ON 1. TIE-IN TAB SHALL BE USED FOR SOIL BENTONITE CUTOFF WALL CONSTRUCTION �M D <br /> o THE FINAL MIX DESIGN AND THE MINIMUM OF FINES PASSING 92DO SIEVE AS APPROVED BY DESIGN AT STA.O+DO -� DELTA WATER STORAGE <br /> ENGINEER. 2. CONTINUOUS TRENCH WITH FULL DEPTH KEY SHALL EXTEND A MINIMUM OF 10' z <br /> BEYOND THE INTERSECTION OF APPROXIMATE 90'TURN OF THE CUTOFF WALL. REVISIONS <br /> NO. DESCRIPTION DATE BY DETAILS <br /> 1 30%REVIEW SET 5-840 SAR <br /> 2 60%REVIEW SET 7-21-20 SAR D E E RE & AU LT 8605.P1RRORT RO.,BIDG.P.BUTE 305 <br /> LGrvGMONT.CO BO506 <br /> SLURRY WALL TIE-IN TAB 3 90%REVIEW SET 8-7-20 SA R eL—.551.14aeFnxwa.eeAn <br /> - NOT TO SCALE 4 ADDITIONAL DRILLING 11-9-20 SAE.DESIGNED BY: SAR APPROVED BY: BAR JOB N0. SHEET: <br /> 5 FOR CONSTRUCTION 3-5-21 SAR <br /> DRAWN BY: ITR PATE:MARCH 2O21 F <br /> 439017.00 Q <br /> CHECKED BY: CJH SCALE:AS NOTED <br />