Laserfiche WebLink
AFL INDUSTRIES,INC. <br /> RIVIERA BEACH, FLORIDA <br /> SERVICE OPERATING AND MAINTENANCE INSTRUCTIONS PAGE 2 OF 2 <br /> MANUAL <br /> PRODUCT: VTC-VERTICAL TUBE COALESCING SEPARATOR <br /> Coalescing Delta-Tubes should also be periodically inspected and cleaned. A good indication that the tubes need <br /> cleaning is a decrease in effluent quality (provided the unit is operated at design flows) or water backing up at the inlet <br /> and separation chamber. For proper cleaning, the tube modules should be removed and steam cleaned or pressure <br /> washed. When pressure washing, use bio-degradable cleaning detergents suitable for grease and oil. <br /> Delta-Pack Removal (if fitted) <br /> Delta-Pack(loam modules). if fitted,can be removed using the included handle for cleaning as required using. To clean <br /> Delta-Pack,follow procedure outlined in(4)above. <br /> 6. Weir Plate Adjustment <br /> VTC models are furnished with one(1)adjustable yN eir Plate located on on top of the Effluent Weir 'gall. <br /> The operating eater level, and in-turn the oil skimming rates, may be adjusted by raisinu or lo"ering the Weir Plate. <br /> MAINTENANCE PROCEDURES <br /> NOTE: In most cases it is not necessary to empty the separator for cleaning. The separator has been designed to collect solids <br /> in specific areas. Solids should be pumped or vacuumed from these collection areas. <br /> I Sludge level accumulation in the influent and separation chambers should be periodically checked. <br /> 2. If pumps,skimmers or other auxiliary equipment is furnished with the separator,refer to Troubleshooting Guide, <br /> 1-0-V1: 2.00-3,contained in this manual. <br /> SUPERSEDES: 1-0-M: 2.10-1 <br />