Laserfiche WebLink
ACZ Laboratories, Inc. � 5 <br /> 2773 Downhill Drive Steamboat Springs, CO 80487 (800)334-5493 <br /> ACZ Project ID. L64296 <br /> ...3 WTI <br /> 9m,•1„� <br /> L64296-01 WG514571 'All Compounds* M8021B/8015D GC/PID/FID Q6 Sample was received above recommended temperature <br /> Benzene M8021 B,'8015D GCGPID/FID 09 Insufficient sample received to meet method QC <br /> requirements <br /> Ethylbenzene M802113/8015D GC;PID/FID Q9 Insufficient sample received to meet method QC <br /> requirements <br /> m p Xylene M8021BI8015D GC/PID/FID 09 Insufficient sample received to meet method QC <br /> requirements <br /> o Xylene M8021 B/8015D GC/PID/FID Q9 Insufficient sample received to meet method QC <br /> requirements <br /> Toluene M80216/8015D GC/PID/FID Q9 Insufficient sample received to meet method QC <br /> requirements <br /> TVH C6 to C10 M8021 B18015D GC/PID/FID Q9 Insufficient sample received to meet method QC <br /> requirements <br /> WG514799 'Ail Compounds* M8015D GC/FID Q6 Sample was received above recommended temperature <br /> TPH C10 to C28 M8015D GC/FID R1 RPD exceeded the method or laboratory acceptance limit <br /> See Case Narrative <br /> M8015D GC/FID RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL) <br /> WG514572 *All Compounds* M826OC/D GC/MS 06 Sample was received above recommended temoerature <br /> Methyl Tert Butyl Ether M8260C/D GC/MS Q9 Insufficient sample received to meet method QC <br /> requirements <br /> L64296-02 WG514571 *All Compounds' M8021 Bi8015D GC/PID/FID Q6 Sample was received above recommended temperature <br /> Benzene M8021 B/8015D GC/PID/FID Q9 Insufficient sample received to meet method QC <br /> requirements <br /> Ethylbenzene M8021 3/8015D GC/PID/FID Q9 Insufficient sample received to meet method QC <br /> requirements <br /> m p Xylene M8021 Bi8015D GC/PID/FID 09 Insufficient sample received to meet method QC <br /> requirements <br /> o Xylene M8021 B/8015D GGFID/FID Q9 Insufficient sample received to meet method QC <br /> requirements <br /> Toluene M802113/8015D GC/PID/FID Q9 Insufficient sample received to meet method QC <br /> requirements <br /> TVH C6 to C10 M8021 B/8015D GC,rPID/FID 09 Insufficient sample received to meet method QC <br /> requirements <br /> WG514799 `AII Compounds* M8015D GGFID Q6 Sample was received above recommended temperature <br /> TPH C10 to C28 M8015D GC/FID R1 RPD exceeded the method or laboratory acceptance limit <br /> See Case Narrative <br /> N18015D GGFID RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> WG514572 *All Compounds' M826OC/D GC/MS Q6 Sample was received above recommended temperature <br /> Methyl Tert Butyl Ether M8260C/D GC/MS Q9 Insufficient sample received to meet method QC <br /> requirements <br /> L64296-03 WG514571 'AII Compounds* M8021B/8015D GC/PID,'FID 06 Sample was received above recommended temperature <br /> REPAID 15 06 05 01 <br /> L64296-2102241528 M2012032 TR12 PAR A3 pg 11 of 125 Page 11 of 15 <br />