My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2021-08-17_REVISION - M1977342
DRMS
>
Day Forward
>
Revision
>
Minerals
>
M1977342
>
2021-08-17_REVISION - M1977342
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/17/2021 4:47:39 PM
Creation date
8/17/2021 3:46:50 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1977342
IBM Index Class Name
Revision
Doc Date
8/17/2021
Doc Name
Adequacy Review Response
From
Climax Molybdenum Company
To
DRMS
Type & Sequence
TR34
Email Name
PSH
JLE
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
146
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Carbon dioxide, refrigerated liquid <br /> PRi4X14IR Safety Data Sheet P-4573 <br /> Making ourplanetmoreproductive- This SIDS conforms to U.S. Code of Federal Regulations 29 CFR 1910.1200, Hazard Communication. <br /> Date of issue:01/01/1997 Revision date: 10/13/2016 Supersedes: 12/18/2014 <br /> DOT Special Provisions(49 CFR 172.102) T75-When portable tank instruction T75 is referenced in Column(7)of the 172.101 Table,the <br /> applicable refrigerated liquefied gases are authorized to be transported in portable tanks in <br /> accordance with the requirements of 178.277 of this subchapter <br /> TP5-For a portable tank used for the transport of flammable refrigerated liquefied gases or <br /> refrigerated liquefied oxygen,the maximum rate at which the portable tank may be filled must <br /> not exceed the liquid flow capacity of the primary pressure relief system rated at a pressure not <br /> exceeding 120 percent of the portable tank's design pressure. For portable tanks used for the <br /> transport of refrigerated liquefied helium and refrigerated liquefied atmospheric gas(except <br /> oxygen),the maximum rate at which the tank is filled must not exceed the liquid flow capacity of <br /> the pressure relief device rated at 130 percent of the portable tank's design pressure. Except <br /> for a portable tank containing refrigerated liquefied helium,a portable tank shall have an outage <br /> of at least two percent below the inlet of the pressure relief device or pressure control valve, <br /> under conditions of incipient opening,with the portable tank in a level attitude. No outage is <br /> required for helium <br /> Additional information <br /> Emergency Response Guide(ERG)Number 120(UN1013) <br /> Other information No supplementary information available. <br /> Special transport precautions Avoid transport on vehicles where the load space is not separated from the driver's <br /> compartment. Ensure vehicle driver is aware of the potential hazards of the load and knows <br /> what to do in the event of an accident or an emergency. Before transporting product containers: <br /> -Ensure there is adequate ventilation.-Ensure that containers are firmly secured.-Ensure <br /> cylinder valve is closed and not leaking.-Ensure valve outlet cap nut or plug(where provided) <br /> is correctly fitted.-Ensure valve protection device(where provided)is correctly fitted. <br /> Transport by sea <br /> UN-No. (IMDG) 2187 <br /> Proper Shipping Name(IMDG) CARBON DIOXIDE, REFRIGERATED LIQUID <br /> Class(IMDG) 2-Gases <br /> MFAG-No 120 <br /> Air transport <br /> UN-No. (IATA) 2187 <br /> Proper Shipping Name(IATA) Carbon dioxide, refrigerated liquid <br /> Class(IATA) 2 <br /> Civil Aeronautics Law Gases under pressure/Gases nonflammable nontoxic under pressure <br /> SECTION • • informationa <br /> 15.1.US Federal regulations <br /> Carbon dioxide,refrigerated liquid(124-38-9) <br /> Listed on the United States TSCA(Toxic Substances Control Act)inventory <br /> SARA Section 311/312 Hazard Classes Immediate(acute)health hazard <br /> Sudden release of pressure hazard <br /> All components of this product are listed on the Toxic Substances Control Act(TSCA) <br /> inventory. <br /> This product or mixture does not contain a toxic chemical or chemicals in excess <br /> of the applicable de minimis concentration as specified in 40 CFR§372.38(a) <br /> subject to the reporting requirements of section 313 of Title III of the Superfund <br /> Amendments and Reauthorization Act of 1986 and 40 CFR Part 372. <br /> 15.2.International regulations <br /> CANADA <br /> Carbon dioxide,refrigerated liquid(124-38-9) <br /> Listed on the Canadian DSL(Domestic Substances List) <br /> EN(English US) SIDS ID: P-4573 7/9 <br /> This document is only controlled while on the Praxair,Inc.website and a copy of this controlled version is available for download.Praxair cannot assure the integrity or <br /> accuracy of any version of this document after it has been downloaded or removed from our website. <br />
The URL can be used to link to this page
Your browser does not support the video tag.