- As a result of the site being in the floodplain,floodwater will submerge the subject north fill area and therefore a <br /> "release"via a failure of the embankment would be unlikely with only a small differential on either side of the <br /> embankment. See attached cross sections. <br /> Critical Sections <br /> Civil Resources observed two sections of the north fill area that were constructed above grade as summarized below: <br /> - West Section: A natural drainage swale exists on the north side of Walker North and this area represents <br /> shallow man-placed fill location. The embankment in this area has an approximate base width of 250 feet and <br /> maximum height of 5.0 feet(spillway el.4946 and native grade at embankment el. of 4941 per Deere-Ault <br /> profile and lidar data, final crest to be 4947). The top width is approximately 80 feet wide and further grading is <br /> being performed to add more fill on the crest and on the downstream side of the embankment. <br /> West Section looking East <br /> East Section:The northeast corner of the North Pond contains a fill area approximately five(5)feet above <br /> native grade(based on lidar data, elevation 4942 and top of embankment 4947). This area has a 40-foot-wide <br /> crest and three horizontal to one vertical (3H:1V)downstream side slopes. Civil Resource met with the SEO on <br /> Tuesday June 1st, 2021 and concluded this is the critical breach section. <br />