Laserfiche WebLink
Sample Date 3/4/2021 <br /> Sampling Location: MW-06 Sample Type Primary Knox Pit M2O17-036 <br /> Depth to Water 6.44 feet <br /> Analyte List Value Units Dissolved Detection Limit Water Quality Standard <br /> ALUMINUM MG/L ND 0.1 **5 <br /> ANTIMONY MG/L ND 0.001 0.006 <br /> ARSENIC MG/L ND 0.002 0.01 <br /> BARIUM MG/L 0.033 0.005 2 <br /> BERYLLIUM MG/L ND 0.0005 0.004 <br /> BORON MG/L ND 0.15 **0.75 <br /> CADMIUM MG/L ND 0.002 0.005 <br /> CHROMIUM MG/L ND 0.01 0.1 <br /> COBALT - MG/L ND 0.005 **0.05 <br /> COPPER MG/L ND 0.02 **0.2 <br /> CYANIDE,TOTAL MG/L ND 0.005 0.2 <br /> FLUORIDE MG/L 0.5 0.1 4 <br /> IRON MG/L ND 0.1 **5 <br /> LEAD MG/L ND 0.002 0.05 <br /> LITHIUM MG/L 0.023 0.02 **2.5 <br /> MANGANESE MG/L ND 0.005 **0.2 <br /> MERCURY MG/L ND 0.0002 0.002 <br /> MOLYBDENUM MG/L 0.0051 0.002 0.21 <br /> _ NICKEL MG/L ND 0.02 0.1 <br /> NITRATE/NITRITE AS N MG/L 0.53 0.02 10 <br /> PH PH 7.26 0.1 **6.5-8.5 <br /> SELENIUM MG/L 0.019 0.01 0.05 <br /> SILVER MG/L ND 0.0005 0.05 <br /> THALLIUM MG/L ND 0.0001 0.002 <br /> TOTAL DISSOLVED SOLIDS MG/L 1900 20 *** <br /> URANIUM MG/L 0.035 0.0001 0.03 <br /> VANADIUM MG/L ND 0.005 **0.1 <br /> ZINC MG/L ND J0.1 **2 <br /> ND= Non-Detect NM= Not Measured <br /> *Analytes tested are from Table 1, Department of Public Health and Environment,WQCC Regulation No.41 unless noted otherwise <br /> **Table 3, WQCC Regulation 41 <br /> *** Table 4,WQCC Regulation 41. Background value x 1.25= Max Allowable TDS <br />