ASME B31.3-2016 <br /> PART 6 and if the designer verifies the serviceability of the mate- <br /> SYSTEMS rial in accordance with para. 323.2.4. <br /> A322 SPECIFIC PIPING SYSTEMS A323.2.2 Lower Temperature Limits,Listed Materials <br /> A322.3 Instrument Piping (a) Materials for use at design minimum tempera- <br /> tures below certain limits must usually be tested <br /> Paragraph 322.3 applies in its entirety,except that ref- to determine that they have suitable toughness for use <br /> erences to paras. A301 and A302.2.4 replace references in Code piping. Table A323.2.2 sets forth those <br /> to paras. 301 and 302.2.4, respectively. p p g <br /> requirements. <br /> A322.6 Pressure-Relieving Systems (b) When materials are qualified for use at tempera- <br /> tures below the minimum temperature listed in <br /> Paragraph 322.6 applies in its entirety, except for Appendix B,the allowable stresses or pressures shall not <br /> para. 322.6.3. See para. A322.6.3. exceed the values for the lowest temperatures shown. <br /> A322.6.3 Overpressure Protection. Paragraph (c) See also the recommended limits in <br /> 322.6.3 applies,except that maximum relieving pressure Table A323.4.2C for reinforced thermosetting resin pipe <br /> shall be in accordance with para. A302.2.4. and in Table A323.4.3 for thermoplastics used as linings. <br /> A323.2.3 Temperature Limits, Unlisted Materials. <br /> PART 7 Paragraph 323.2.3 applies. <br /> MATERIALS <br /> A323.2.4 Verification of Serviceability. When an <br /> A323 GENERAL REQUIREMENTS unlisted material is to be used,or when a listed material <br /> A323.1 Materials and Specifications is to be used above or below the limits in Appendix B <br /> Paragraph 323.1 applies except for para. 323.1.4. See <br /> or Table A323.4.2C or Table A323.4.3,the designer shall <br /> comply with the requirements of para. 323.2.4. <br /> para. A323.1.4. <br /> A323.1.4 Reclaimed Materials. Reclaimed piping A323.4 Fluid Service Requirements for Nonmetallic <br /> components may be used, provided they are properly Materials <br /> identified as conforming to a listed or published specifi- <br /> cation(see para.323.1.1)and otherwise meet the require- <br /> ments of this Code. The user shall verify that (a) Nonmetallic materials shall be safeguarded <br /> components are suitable for the intended service. Suffi- against excessive temperature, shock, vibration,pulsa- <br /> cient cleaning, examination, and testing shall be per- tion, and mechanical abuse in all fluid services. <br /> formed to determine the minimum available wall (b) Requirements in para. A323.4 apply to pressure- <br /> thickness and freedom from any of the following to containing parts. They do not apply to materials used <br /> an extent that would be unacceptable in the intended for supports,gaskets, or packing. See also Appendix F, <br /> service: para. FA323.4. <br /> (a) imperfections <br /> (b) reduction of mechanical properties, or A323.4.2 Specific Requirements <br /> (c) absorption of deleterious substances (a) Thermoplastics <br /> (1) They shall not be used in flammable fluid ser- <br /> A323.2 Temperature Limitations vice above ground, unless all of the following are met: <br /> The designer shall verify that materials that meet other (a) The size of the piping does not exceed DN 25 <br /> requirements of the Code are suitable for service (NPS 1). <br /> throughout the operating temperature range. Also see (b) Owner's approval is obtained. <br /> the Notes for Tables B-1 through B-5 in Appendix B. (c) Safeguarding in accordance with Appendix G <br /> A323.2.1 Upper Temperature Limits,Listed Materials is provided. <br /> (a) Except as provided in (b)below,a listed material (d) The precautions of Appendix F, paras. <br /> shall not be used at a design temperature higher than F323.1(a) through (c) are considered. <br /> the maximum for which a stress value or rating is shown, (2) They shall be safeguarded when used in other <br /> or higher than the maximum recommended temperature than Category D Fluid Service. <br /> in Table A323.4.2C for RTR materials and in (3) PVC and CPVC shall not be used in compressed <br /> Table A323.4.3 for thermoplastics used as linings. air or other compressed gas service. <br /> (b) A listed material may be used at a temperature (b) Reinforced Plastic Mortars (RPM) Piping. This pip- <br /> higher than the maximum stated in (a)above if there is ing shall be safeguarded when used in other than <br /> no prohibition in Appendix B or elsewhere in the Code, Category D Fluid Service. <br />