My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2021-06-24_REVISION - M2012032
DRMS
>
Day Forward
>
Revision
>
Minerals
>
M2012032
>
2021-06-24_REVISION - M2012032
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/24/2021 1:16:54 PM
Creation date
6/24/2021 12:14:09 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M2012032
IBM Index Class Name
Revision
Doc Date
6/24/2021
Doc Name
Adequacy Review Response #3
From
Ouray Silver Mines, Inc.
To
DRMS
Type & Sequence
TR14
Email Name
LJW
Media Type
D
Archive
No
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1249
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ASME B31.3-2016 <br /> of reinforcement shall be qualified as required by A304.7 Pressure Design of Other Components <br /> para. A304.7.2 except as provided in para. A304.3.2. A304.7.1 Listed Components. Other pressure con- <br /> A304.3.2 Branch Connections Using Fittings. It may taining components, manufactured in accordance with <br /> be assumed without calculation that a branch connection standards in Table A326.1 but not covered elsewhere in <br /> has adequate strength to sustain the internal and exter- para. A304, may be utilized in accordance with <br /> nal pressure that will be applied to it if it utilizes a fitting para. A303. <br /> (a tee,lateral, or cross) in accordance with para. A303. A304.7.2 Unlisted Components. Pressure design of <br /> A304.3.3 Additional Design Considerations. The unlisted components and joints,to which the rules else- <br /> requirements of paras. A304.3.1 and A304.3.2 are where in para. A304 do not apply, shall be based on <br /> intended to assure satisfactory performance of a branch calculations consistent with the design criteria of this <br /> connection subjected only to internal or external pres- Code.Calculations shall be substantiated by one or both <br /> sure. The designer shall also consider paras. 304.3.5(a), of the means stated in (a) and (b) below, considering <br /> (c), and (d). applicable ambient and dynamic effects in paras. 301.4 <br /> through 301.11. <br /> A304.4 Closures (a) extensive, successful service experience under <br /> Closures not in accordance with para. A303 shall be comparable design conditions with similarly propor- <br /> qualified as required by para. A304.7.2. tioned components made of the same or like material <br /> (b) performance test under design conditions includ- <br /> A304.5 Pressure Design of Nonmetallic Flanges ing applicable dynamic and creep effects,continued for <br /> a time period sufficient to determine the acceptability <br /> (16) A304.5.1 General of the component or joint for its design life <br /> (a) Flanges not in accordance with para. A303, or For (a) or (b) above, the designer may interpolate <br /> A304.5.1(b) or (d) shall be qualified as required by between sizes, wall thicknesses, and pressure classes, <br /> para. A304.7.2. and may determine analogies among related materials. <br /> (b) Flanges for use with flat ring gaskets may be A304.7.3 Nonmetallic Components With Metallic <br /> designed in accordance with the BPV Code,Section VIII, Pressure Parts. Components not covered by standards <br /> Division 1, Appendix 2, except that the allowable in Table A326.1,in which both nonmetallic and metallic <br /> stresses and temperature limits of this Code shall gov- <br /> ern.Nomenclature shall be as defined in the BPV Code, parts contain the pressure,shall be evaluated by applica- <br /> ble requirements of para. 304.7.2 as well as those of <br /> except for the following: <br /> P = design gage pressure para. A304.7.2. <br /> SQ = bolt design stress at atmospheric temperature <br /> Sb = bolt design stress at design temperature PART 3 <br /> Sf = allowable stress for flange material from FLUID SERVICE REQUIREMENTS FOR PIPING <br /> Table B-1, B-2, or B-3 COMPONENTS <br /> (c) The rules in (b) above are not applicable to a A305 PIPE <br /> flanged joint having a gasket that extends outside the Listed pipe may be used in Normal Fluid Service, <br /> bolts (usually to the outside diameter of the flange). subject to the limitations of the pressure-containing <br /> (d) For flanges that make solid contact outside the material and para. A323.4. Unlisted pipe may be used <br /> bolts, Section VIII, Division 1, Appendix Y should be only in accordance with para. A302.2.3. <br /> used. <br /> A304.5.2 Blind Flanges. Blind flanges not in accor- A306 FITTINGS, BENDS, MITERS, LAPS, AND <br /> dance with para. A303 may be designed in accordance BRANCH CONNECTIONS <br /> with para. 304.5.2, except that allowable stress S shall <br /> be taken from Tables in Appendix B. Otherwise, they General. Fittings,bends,miters,laps,and branch con- <br /> shall be qualified as required by para. A304.7.2. nections may be used in accordance with paras. A306.1 <br /> through A306.5. Pipe and other materials used in such <br /> A304.6 Reducers components shall be suitable for the manufacturing pro- <br /> Reducers not in accordance with para. A303 shall be cess and the fluid service. <br /> qualified as required by para. A304.7.2. A306.1 Pipe Fittings <br /> A306.1.1 Listed Fittings. Listed fittings maybe used <br /> 4 Bolt design stresses shall not exceed those in Table A-2 or in Normal Fluid Service subject to limitations on <br /> Table A-2M. materials. <br />
The URL can be used to link to this page
Your browser does not support the video tag.